First Use 
 

Only qualified or trained personnel should use this appliance. 

 

Switch on the water and electricity supplies.  Leave the boiler to fill for 30 minutes. 
 
Drain off approximately 5 litres of water to remove any loose carbon particles from the 
filter. 
 

Regular Operation 
 

The boiler starts automatically when the water supply is turned on.  During the heating 
cycle, only small quantities of water are added to ensure hot water is always available 
at the dispenser. 
 
The boiler is designed to be permanently switched on: it is only necessary to turn it off 
for de-scaling or maintenance. 
 
Water is drawn off through the dispenser (G). 
 

Adjustment 

– Water temperature, screen backlight and contrast 

 
Consult Fig 1. 
 
Turn power off and on again.  The FilterFlow screen (B) is displayed on the control 
panel (A). 
 
Press and hold the 

power

 button (D) until the software version is displayed.  Press the 

function button 

Fn

 (C) and the temperature will be displayed. 

 
Press the 

power

 button to cycle through the values 70 to 96 Deg C.  Press the 

Fn

 

button to select the required value. 
 
The backlight adjustment screen is displayed next.  Press the 

power

 button to cycle 

through the values 1-25.  Press the 

Fn

 button to select the required value. 

 
The contrast adjustment screen is displayed next.  Press the 

power

 button to cycle 

through the values 35 to 60.  Press the 

Fn

 button to select the required value. 

 
Press the 

power

 button to exit. 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EB3F/PB

Page 1: ... Button Water Boilers EB3F PB and EB3F PBM Please make a note of your product details for future use Date Purchased _________________________ Model Number __________________________ Serial Number __________________________ Dealer _________________________________ _______________________________________ ...

Page 2: ...rmation and Guarantee 11 IMPORTANT INFORMATION Read these instructions carefully before using this product paying particular attention to all sections that carry warning symbols caution symbols and notices Ensure that these are understood at all times WARNING This symbol is used whenever there is a risk of personal injury CAUTION This symbol is used whenever there is a risk of damaging your Lincat...

Page 3: ... all times Strip plastic coating and clean the appliance before use During operation parts may become hot avoid accidental contact Disconnect this appliance before servicing maintenance or cleaning TECHNICAL DATA Model Height mm Width mm Depth mm Weight kg EB3F PB 655 290 465 13 0 CHECK LIST OF ENCLOSURES Warranty card Instructions manual Drip tray and insert Inlet hose with BSP connection FilterF...

Page 4: ...mounting kits see Accessories Power Ratings Model kW Ambient temperature Deg C Water inlet pressure bar Water inlet pressure kPa EB3F PB 3 0 5 to 30 1 to 8 100 to 800 The EB3F PB is supplied with a 13 amp plug Water supply and waste connection Connect the supplied white water inlet hose to the inlet connection point on the base of the boiler and the other end to the supply via an accessible isolat...

Page 5: ...IS425 ECN 3607 Page 5 of 13 OPERATING INSTRUCTIONS Fig 1 ...

Page 6: ...e Water is drawn off through the dispenser G Adjustment Water temperature screen backlight and contrast Consult Fig 1 Turn power off and on again The FilterFlow screen B is displayed on the control panel A Press and hold the power button D until the software version is displayed Press the function button Fn C and the temperature will be displayed Press the power button to cycle through the values ...

Page 7: ...After a few seconds the programming mode is entered Push the Fn button until the Use dispense screen is visible Pressing set turns off the timed dispense and the unit changes to Push and hold for dispensing Press next Press set to select 1 2 or 3 measured dispenses Press next Press yes to select to set the dispense volumes Or next to exit Select the size to set Press OK Press and hold the Hot wate...

Page 8: ...e used without a filter but scale will quickly build up and water taste may be affected Fig 2 To replace the filter Remove the drip tray from the appliance Pull the bottom of the lower panel Fig 1 F outwards and release the two spring pins Slide the panel downwards to remove Twist the base of the filter 90 degrees to the left and lower the cartridge out of the appliance It will contain a small amo...

Page 9: ...working day gives the de scaling agent several hours to work Lincat recommend our own de scaling agent MS19 available from our Spares department Wear protective clothing Isolate the boiler from the electrical supply Turn off the power and allow the water to cool to 60 Deg C Using a 3mm allen key remove the screw in the top of the boiler Remove the insulation from the top of the tank Unscrew and re...

Page 10: ... on these appliances should be carried out by one of our recommended service engineers The control panel displays information that can help with fault diagnosis Before calling for service draw off a litre of water clear the fault code by pressing the Fn button and turn the boiler off and on again at the supply If the fault persists call service for advice Message displayed Possible causes Correcti...

Page 11: ...zle DV02 Service valve EBM05 Outer lid EL235 Element FC02 Filter cartridge FH02 Filter head GA48 Lid gasket LE47 Level sensor insulator LE48 Upper level sensor LE49 Lower level sensor PI12 Inlet hose PL202 Mains cable PR77 Circuit board SO24 Solenoid valve SV03 Dispenser solenoid valve SW86 Dispenser switch TH87 95o cutout thermostat TH88 120o cutout thermostat TH98 Thermistor SPARE PARTS LIST FIL...

Page 12: ...an routine cleaning should be carried out by one of our authorised service agents We cannot accept responsibility for work carried out by other persons To ensure your service enquiry is handled as efficiently as possible please tell us Brief details of the problem Product code All available on serial plate Type number Serial number Lincat reserve the right to carry out any work under warranty give...

Page 13: ...ufacturer disclaims any liability for incidental or consequential damages Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work Service calls to equipment under warranty will be carried out in accordance with the conditions of sale Unless otherwise specified a maximum of 15 minutes of administrative time not spent directly carry...

Reviews: