I/O Specifications

21

2019 © LINAK A/S

IO-Link

Input/Output

Specification

Comments

Description

IO-Link is standardised IO technology (IEC 61131-9) 
for the communication with actuators. The point-to-point 
communication is based on the long established actuator 
connection without additional requirements regarding the cable 
material. IO-Link is no fieldbus but the further development of 
the existing, tried-and-tested connection technology for 
actuators.

Brown
(M12 port 2)
2L+

Power supply motor +

24 VDC + (VCC)
Connect Brown to positive

Note: 
Do not change the power supply polarity on the brown and 
blue wires!
Power supply GND (-) is electrically connected to the housing
Current limit levels can be adjusted through BusLink
If the temperature drops below 0°C, all current limits will 
automatically increase to 6A for 24V.
24V ± 10% - max. 2.5A depending on load
24V, current limit 5A

Blue
(M12 port 5)
2M

Power supply motor -

24 VDC - (GND)
Connect Blue to negative

Red
(M12 port 1)
L+

IO-Link
18 - 30 VDC +

On voltage:
18 to 30 V

M12 plug on device

M12 Plug on device

3

2

1

4

5

2L

2M

 

L-

 

C/Q

 

L+

 

 - pin numbering and connections.

Black
(M12 port 3)
L-

I

O-Link supply -

18 - 30 VDC - (GND)

Green
(M12 port 4)
C/Q

I

O-Link C/Q

(data communication)

IO-Link is fieldbus independent and can be integrated into all 
fieldbus systems worldwide.
Transmission rate:  38.4 kbaud (COM 2)
Max cable length:  15 meters
The IODD file describes the parameters, find it here:

https://ioddfinder.io-link.com 

Violet

Service interface

Only BusLink can be used as service interface. 
Make sure that the violet and white wires are not short-circuited 

White

Service interface GND

Yellow

Not used

Please note that version 1.0 of IO-Link does not support data storage. Therefore, it is recommended to disable the 
data storage feature on the PLC/IO-Link master.

Data storage is a recommended feature in IO-Link, which makes it easy to replace an existing device with a substitute.
Data storage will be released in a later software version.