Connection diagram
20
2019 © LINAK A/S
IO Link (November 2020)
25XXXXXXXXXXAB1X=XXXXXXXXXXXXX
Please be aware that if the power supply is not properly connected, you might damage
the actuator!
An IODD file describes the IO-Link parameters for
easy PLC configuration
.
The newest version is available online at the offi cial IO-Link IODDfi nder:
BROWN
BLUE
RED
GREEN
WHITE
VIOLET
DATA
DATA GND
M
H-Bridge
L+
C/Q
Version B
BLACK
L-
Connects to:
Actuator
Flying leads:
M12 Port
Class B
2L+
Brown
2
2M
Blue
5
L+
Red
1
C/Q
Green
4
L-
Black
3
The LA25 with IO-Link and M12 connector is a plug-and-
play solution. If flying leads is the preferred option, please be
aware that the LINAK cable colours differ from the IO-Link
standard. The cable colours from the actuator and the M12
port numbers are specified in the table below. In a setup
where the violet and white wires are not used, we strongly
recommend insulating these to avoid short circuits and even-
tually damaging the actuator.
M12 Plug on device
3
2
1
4
5
2L
+
2M
L-
C/Q
L+
M12 CONNECTOR
2L+
(motor +)
2M
(motor -)
We offer a service interface called
BusLink
with features like e.g. diagnostics, manual run and confi guration
The newest version is available online at
LINAK.COM/
TECHLINE
Please note: The BusLink confi guration cable must be purchased seperately
Item number for BusLink cable kit: 0965348-A (a USB2Lin)