READ AND WRITE
Parameter and diagnostic data
On the IO-Link master, there are standard IO-Link parameters available such as e.g. Product ID and firmware revi-
sion. There are also LINAK specific parameters available. These include configuration of the beaviour in outwards
and inwards direction and historic usage data used for diagnostics:
F O R M O U N T I N G I N S T R U C T I O N S A N D G U I D A N C E I N U S A G E , P L E A S E S E E T H E R E L E V A N T U S E R M A N U A L S
Copyright © LINAK
2021.11
. MA-M9-02-844
. LINAK
A/S reserves the right to mak
e technical alter
ations
READ ONL
Y
LINAK specific parameters
Index Field size
Description
Comment
Resolution/encoding
4096
U8
Current limit out
Set a default current limit
0.25 A/bit
4097
U8
Current limit in
4098
U16
Soft start time out
Set ramp-up speed settings
1 ms/bit
4099
U16
Soft start time in
4100
U16
Soft stop time out
Set ramp-down speed settings
(0 = instant stop or set a value ≥ 300 ms)
1 ms/bit
4101
U16
Soft stop time in
4103
U16
Virtual limit - outwards
Set a virtual limit to stop before the physical
endstop
0.1 mm/bit
4104
U16
Virtual limit - inwards
4107
U32
Unique identification number
General information
U32 number
4111
U32
Software configuration number
4113
U8
Max. current seen
Monitor the max. current level (A)
0.25 A/bit
4115
U8
Max. temperature seen
Monitor the min. and max.
temperature level (°C)
1 °C/bit (-40 °C offset)
4116
U8
Lowest temperature seen
4118
U32
Total runtime
Monitor the total runtime (s)
1 s/bit
4119
U16
Reason for last stop
(error codes)
0 = none, 1 = H-bridge fault, 2 = Temperature error, 4 = Undervoltage, 8 = Overcurrent,
16 = Internal PSU failure, 32 = EOS fault, 64 = Hall fault, 256 = Overvoltage,
512 = Position not changing, 1024 = Current measurement HW failure
4126
U8
Number of LINAK current overloads out
Monitor the number of times the actuator has
stopped on the factory set current limit
1 time/bit
4127
U8
Number of LINAK current overloads in
4128
U8
Number of customer overloads out
Monitor the number of times the actuator has
stopped on the customer specific current limit
4129
U8
Number of customer overloads in
4131
U32
Number of end of stroke out
Monitor the number of endstop signals in each
direction
4132
U32
Number of end of strokes in
4133
U32
Number of starts out
Monitor the number of starts in each
direction
4134
U32
Number of starts in
4135
U32
Total piston distance
Monitor the distance travelled (m)
5 m/bit
4136
U32
Actuator production order number
General information
U32 number