background image

F O R   M O U N T I N G   I N S T R U C T I O N S   A N D   G U I D A N C E   I N   U S A G E ,   P L E A S E   S E E   T H E   R E L E V A N T   U S E R   M A N U A L S

Copyright © LINAK 

2021.11 

. MA-M9-02-844

 . LINAK 

A/S reserves the right to mak

e technical alter

ations

Terms of use

The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing 
accurate and up-to-date information on its products. 
However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and 
changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. 
While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability 
of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed 
in its catalogues or other written material drawn up by LINAK.
All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK.

Summary of Contents for BusLink LA25

Page 1: ...LINAK COM TECHLINE Actuator LA25 IO Link Quick start guide Version 1 1...

Page 2: ...lours from the actuator and the M12 port numbers are specified in the table below In a setup where the violet and white wires are not used we strongly recommend insulating these to avoid short circuit...

Page 3: ...supply 18 30 VDC On voltage 18 to 30 V M12 plug on device M12 Plug on device 3 2 1 4 5 2L 2M L C Q L pin numbering and connections Black M12 port 3 L IO Link supply 18 30 VDC GND Green M12 port 4 C Q...

Page 4: ...r LA25 The table below provides an overview of the input and output data Data name Byte Field size Details Set position Run command 0 1 16 bit 0x0000 0xFFEF 0 65519 0xFFFB 0XFFF0 65520 65531 0xFFFC 65...

Page 5: ...dentification number General information U32 number 4111 U32 Software configuration number 4113 U8 Max current seen Monitor the max current level A 0 25 A bit 4115 U8 Max temperature seen Monitor the...

Page 6: ...otor seperately read more here Plug in the M12 connector or wire up the actuator with flying leads to the master Make sure you receive data from the actuator Indicating that communication is OK Make s...

Page 7: ...on the product label max 2 5 amps on a standard LA25 Still experiencing problems with your actuator Please contact your local LINAK office for technical support Where can I find the latest IODD file...

Page 8: ...O U N T I N G I N S T R U C T I O N S A N D G U I D A N C E I N U S A G E P L E A S E S E E T H E R E L E V A N T U S E R M A N U A L S Copyright LINAK 2021 11 MA M9 02 844 LINAK A S reserves the rig...

Page 9: ...elopment in order to improve its products LINAK products are subject to frequent modifications and changes without prior notice Therefore LINAK cannot guarantee the correct and actual status of said i...

Reviews: