background image

14

English

3. Connect the test leads across with the object being measured. The measured value shows on 

the display. 

 

Capacitance 

(See fig 1) 

1. Turn the rotary switch to 

  position.   

3. Push REL 

Δ

 button. 

4. Connect the test leads across with the object being measured. The measured value shows on 

the display. 

To minimize the measuring error caused by the distributed capacitor, the testing lead should be 

short as possible. For measuring capacitance higher than 10 µF, it is normal taking several 

seconds to obtain a reading. 

 

Replacing the battery  

 (See fig 2) 

1. Disconnect the connection between the testing leads and the circuit under test when battery 

indicator appears on the display. 

2. Turn the Meter to OFF position. 

3. Remove the screw, and separate the case bottom. 

4. Replace the battery with a new 3V battery type CR2032. 

Summary of Contents for 210

Page 1: ...1 Illustrations ...

Page 2: ...2 Tables ...

Page 3: ...3 Tables ...

Page 4: ...4 Tables ...

Page 5: ...5 Tables ...

Page 6: ...6 Tables ...

Page 7: ...7 210 English 8 Svenska 19 Norsk 25 Dansk 29 Suomi 37 Deutsch 44 Netherlands 52 Français 60 Italiano 68 Español 76 Português 83 Ελληνικά 90 Polski 98 Eesti 106 Lietuviškai 113 Latviski 121 ...

Page 8: ...8 English Limit 210 Contents Overview General specification Safety information Button function Voltage DC and AC Resistance Diode testing Continuity test Frequency Capacitance Battery ...

Page 9: ...ions fashionable design and highly reliable hand held measuring instrument General Specifications Measuring range and accuracy see page 2 Max Voltage 600 V Auto ranging Sleep mode Automatic turn off if not in use for 10 minutes Display 3 digits or 3999 Measurement Speed Updates 3 times second Temperature Operating 0 C 40 C 32 F 104 F Storage 10 C 50 C 14 F 122 F Battery Type One pcs 3V type CR2032...

Page 10: ... damaged or the case or part of the case is removed Look for cracks or missing plastics Pay attention to the insulation around the connectors Inspect the test leads for damages insulation or exposed metal Do not apply more than the rated voltage as marked on the Meter The rotary switch should be placed in the right position and no any changeover during measurement is conducted to prevent damage of...

Page 11: ...rent Replace the battery as soon as the battery indicator appears Whit to low battery the Meter might produce false readings that can lead to electric shock and personal injury Functional buttons SELECT Change between Ω Diodes test or Continuity test when rotary switch are selected for any of this functions REL Δ On Off for relative mode in any measuring mode except frequency duty mode Display sho...

Page 12: ...measured value shows on the display Resistance measurement See fig 1 1 Turn the rotary switch to Ω position 2 Select Ω with SELECT button Display shows resistance symbol Ω 3 Connect the test leads across with the object being measured The measured value shows on the display The test leads can add 0 1Ωto 0 3Ωof error to resistance measurement To obtain precision readings in low resistance measureme...

Page 13: ...iode symbol 3 Place the red test lead on the component s anode and place the black test lead on the component s cathode The measured value shows on the display Continuity test See fig 1 1 Turn the rotary switch to Ω position 2 Select Continuity with SELECT button Display shows Continuity symbol 3 Connect the test leads across the object The buzzer sounds if the resistance of a circuit under test i...

Page 14: ...nimize the measuring error caused by the distributed capacitor the testing lead should be short as possible For measuring capacitance higher than 10 µF it is normal taking several seconds to obtain a reading Replacing the battery See fig 2 1 Disconnect the connection between the testing leads and the circuit under test when battery indicator appears on the display 2 Turn the Meter to OFF position ...

Reviews: