LD25x
7.3 Model LD251: additional settings for the analogue output
The Basic menu provides the following additional settings:
Menu
Setting Range
Default
A-ChAr
Analogue characteristics
Select one of the following options:
-0_10
+/-10 V (bipolar)
-10_10
0-10 V (positive output only)
0_10
4-20 mA current output
4_20
0-20 mA current output
0_20
With s/-10 Volts the polarity of the output
voltage will follow the sign in the display.
OFFSEt
Analogue Offset
Set this parameter to 0 when you expect your
analogue signal to start with 0 V (or 0 mA / 4 mA
respectively). When another zero definition is
desired it can be set via this parameter. Setting of
e.g. “5.000” will already produce 5 volts with the
output in zero state.
-9,999 ... +9,999
0
GAin
Analogue Gain
It is meant to set the analogue output swing.
Setting 10.00 will allow full swing of 10 V or 20
mA, setting 8.00 will reduce the swing to 8 V or 16
mA.
00,00 ... 99,99
10
The following Operational parameters provide scaling of the analogue output:
Menu
Setting Range
Default
AnAbEG
Analogue-Begin
Start value of the analogue conversion range.
-199999 ...
999999
0
AnAEnd
Analogue-End
End value of the analogue conversion range.
-199999 ...
999999
10000
By means of the two above parameters any window of the whole display range
can be mapped onto the analogue output.
MAN LD25x E 1.0.odt
Set-up procedure
19 of 44