IF50
6.2.2 Settings for special applications
When you find that the standard settings listed above are not suitable for your
specific application, please scroll through the following setting options and find
out the input level and characteristic that meet your needs.
DIL1
DIL2
Input A characteristics
Input B characteristics
5 6 7
3 4 5 6
x
x
0 0 0 1
TTL level (A)
TTL level (B)
x
x
0 0 1 0
HTL level (A and /A)
HTL level (B and /B)
x
x
0 0 1 1
TTL level (A)
TTL level (B and /B)
x
x
0 1 0 0
TTL level (A and /A)
TTL level (B)
x
x
0 1 0 1
HTL level NPN (A)
HTL level PNP (B)
x
x
0 1 1 0
HTL level NPN (A)
TTL level (B and /B)
x
x
0 1 1 1
HTL level NPN (A)
TTL level (B)
x
x
1 0 0 0
HTL level PNP (A)
TTL level (B and /B)
x
x
1 0 0 1
HTL level PNP (A)
TTL level (B)
x
x
1 0 1 0
HTL level PNP (A)
HTL level NPN (B)
x
x
1 0 1 1
TTL level (A and /A)
HTL level NPN (B)
x
x
1 1 0 0
TTL level (A)
HTL level NPN (B)
x
x
1 1 0 1
TTL level (A and /A)
HTL level PNP (B)
x
x
1 1 1 0
TTL level (A)
HTL level PNP (B)
6.3 Analogue output format
The desired output format of the analogue output can be set by means of
positions 1 and 2 of switch DIL2
.
DIL2
Output format
1 2
0 0
Voltage 0 … +10 V
This format allows the setting via PC through the parameter
. Since the factory default setting of
is “1”, the format will be “0 … +10
V” output under default conditions.
0 1
Voltage -/+ 10 V
1 0
Current 4 – 20 mA
1 1
Current 0 – 20 mA
MAN IF50 I_E 1.0.odt
6 - DIL switch settings
51 / 80