IF50
11.5 Analogue settings
Teach Minimum
Teach Maximum
These settings define the minimum and maximum count for either input A or
A/B quadrature, when the analogue output range is between 0 V and 10 V.
You can enter the minimum and maximum settings as follows.
1. Press the TEACH button (as described in the section “7.1 Operation as a
single channel counter (without direction signal) or as a positional
counter (with direction signal)” on page 53). The TEACH result will be
available in the INPUTS pane in the main window of the operator
program after pressing the READ key.
2. Enter the counter settings directly in the parameter field of your screen,
without using the TEACH function. Please store parameters either by
pressing the ENTER key or – after you complete all entries – by pressing
the TRANSMIT ALL key first and then the STORE EEPROM key.
NOTE
When using the sum mode (A+B) or the differential modes (A-B) -see parameter
on page 59-, these settings already refer to the sum or to the
difference of the counter.
Output Mode
This register allows the operator to select the output format of the analogue
outputs as shown in the Figure:
Analogue Offset
This register allows to adjust the analogue zero output over the full range
(either -9999 mV ... 0 ... +9999 mV or -19998 µA ... 0 ... +19998 µA).
Analogue Gain
This register sets the maximum output swing of the analogue output. Setting
1000 will result in an output swing of either 10 volts or 20 milliamps.
MAN IF50 I_E 1.0.odt
11 - Parameter settings
63 / 80