65
1. Overview
2. Setup & Use
3. Optional
Accessories
4. T
roubleshooting
5. W
arranty
, Safety
& Specifications
<CMD>
Symbol
Hex
Value
<Param> Value
Definition
IIAV?
0xB5
Command Packet:
The controller sends no
<Param> character in the
command packet.
Response Packet:
The CAT 860 sends two
<Param> characters in
the response packet. The
possible values are shown
below:
<Param> #1:
0x80 = IR Channel A
0x81 = IR Channel B
<Param> #2:
0xCF = 0 dB
0xCE = -1dB
0xCD = -2dB
0xCC = -3dB
0xA7 = -40dB
0x83 = -76dB
0x82 = -77dB
0x81 = -78B
0x80 = -79dB
14. RS-232 SERIAL INTERFACE
COMMAND DEFINITION
CONT’D
Definition:
This command causes the CAT 860 to return a query response packet
where the first of two <Param> characters contains the selection status set by
IICH (<0xB0>) and the second contains the value stored in the volume-level
EEPROM variable selected by the IICH (<0xB0>) command.
If the command is not received properly, the CAT 860 responds by sending a
<NACK> character.
ADVANCED COMMAND SET FOR AUDIO MIXER OPERATIONS CONT’D
Audio Input Functions for the Infrared Source Group Cont’d
5. QUERY ABSOLUTE VOLUME FOR SELECTED INFRARED INPUT
COMMAND
Summary of Contents for CAT 860