![background image](http://html1.mh-extra.com/html/lightronics/sc910d/sc910d_owners-manual_1914923010.webp)
Page 10 of 13
SC910D/SC910W DMX CONTROLLER
Version 2.1
OWNERS MANUAL
11/02/2020
www.lightronics.com
Lightronics Inc.
509 Central Drive Virginia Beach, VA 23454
757 486 3588
active at any given time.
Other scenes (not part of that group) can be on at the
same time as scenes in a group.
Unless you are going to set one or two simple groups of
non-overlapping scenes you may want to experiment
with the settings to get different effects.
SETTING SCENES TO BE PART OF A MUTUALLY
EXCLUSIVE GROUP
(Function Codes 41 - 44)
After accessing a function (41 - 44) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The scene lights will show which scenes are part of
the group.
2. Use the scene buttons to toggle scenes on/off for
the group.
3. Push REC to save the new group set.
Scenes within the Mutually Exclusive Group will
operate with a Last Takes Precedence merge but will
still pile on to the input DMX signal.
SETTING FADER STATION STARTING SCENE
(Function Codes 51-54)
Several pushbutton and fader stations can be used to
access different scene blocks on the SC910. This allows
for the use of two different smart stations set to different
Architectural Unit ID Numbers, also referred to here as
“Station ID”, to control two different blocks of scenes.
The scene blocks are created using the Station ID #
functions and selecting the first scene in a block. The
pushbuttons scenes set on the SC910 are scenes 1-8,
whereas the scenes assigned to the SC910 faders are
scenes 9-18. Scenes 1-16 are assignable to remotes
leaving scene 17 & 18 specifically for SC910 control.
After accessing a Fader ID function # (51 - 54), using
the steps outlined in ACCESSING AND SETTING
FUNCTIONS, the indicators for the current starting
scene will flash back as a four digit code. The following
steps will allow you to change the current setting.
1. Input the number of the scene you wish to have
assigned to fader 1 on the AF as a four digit number.
2. Press the record button to save your selection.
For example, referring back to the diagram on page 4 of
this manual, you can have an AC1109 and an AF2104
set to Fader ID # 1. By pressing REC, CHN MOD, 5, 1,
CHN MOD, 0, 0, 0, 9, REC. The AC1109 would
operate scenes 1-8 and off while the AF2104 would
recall and fade 9-12
FACTORY RESET
(Function Code 88)
A Factory Reset will invoke the following conditions:
1. All scenes will be erased.
2. All fade times will be set to three seconds.
3. Simple switch functions will be set as follows:
Input #1 Turn ON Scene 1
Input #2 Turn OFF Scene 1
Input #3 Toggle Scene 2 ON and OFF
4. All System Configuration Options (Function Codes
37 and 38) will be turned OFF.
5. Mutually Exclusive groups will be cleared (no
scenes in the groups).
6. Fader Station Starting Scene settings will be cleared.
6. DMX Fixed Channel settings will be cleared.
TO PERFORM A FACTORY RESET
After accessing the function (88) as described in
ACCESSING AND SETTING FUNCTIONS:
1. The OFF(0) light will repeat a pattern of 4
flashes.
2. Enter
0910
(the model number of the product).
3. Push REC. The scene lights will flash briefly and
the unit will return to its operating mode.
MAINTENANCE AND REPAIR
TROUBLESHOOTING
No LEDs lit when plugged in.
-Verify that SC910 12V power supply is plugged into a
working outlet and the LED on the power supply is lit.
-Verify DMX input and power connections as well as
their polarity.
- Push the OFF/CLR button. When pushed the red LED
next to it should illuminate.