3.

Administrator password system setup command table

No

Setting item

Add

Data

(XY)

Remark

Factory

Default

1

Coding of Remote

Controller

21

X

X=#

2

Remote Controller

Deleting

22

X

X=#

3

Coding of Detector

23

X

X=02~99

4

Single Wireless Detector

Deleting

24

X

X=02~99

5

All Wireless Detectors

Deleting

25

X

X=#

6

Wireless Alarm Type

Setting

26

XY

X=02~99

Y=0~3

7

Wired Alarm Type Setting

47

XY

X=81~88

Y=0~3

8

Wireless Equipment

Coding Setting

27

XXXX

XXXX

XXXXXXXX=8 digit

wireless equipment coding

9

User ID Setting

28

XXXX

XXXX= 4 digit user number

10

Siren Prompt Setting

31

X

X=1 siren prompt open

X=0 siren prompt closed

11

Siren Ring Time Setting

32

X

X=00~15 minutes

3 minutes

12

Arm Time Delayed

33

X

X=00~99 seconds

0 second

13

Alarm Time delayed

34

X

X=00~99 seconds

0 seconds

14

Telephone Dial-up Cycle

Times

35

X

X=00~09 times

9 times

15

Remote Call Ring Times

36

X

X=0~9 times

9 times

16

Artificial Recording

37

X

X=#, play automatically after

recording

17

Change User Password

38

XXXX

XXXX= 4 digit

1234

18

Change Administrator

Password

39

XXXX

XXXX= 4 digit

6666

19

Keypad Lock Setting

40

X

X=1 open,

X=0 closed

0

20

Host Timing Setting

41

X

X=1 open time setting function

X=0 close time setting function

0

21

Host Arm or Disarm

Setting

42

XXXX

YYYY

XXXX= arm time YYYY= disarm

time

22

Host Reset

43

X

X=#

23

Historical Records

Inquires

44

X

X=#

24

Host Historical Records

Deleting

45

X

X=#

25

Arm/ Disarm Upload to

Center

46

X

X=1 inform Receiving Center

X=0 don’t

inform Receiving

Center

26

Clock Setting

48

XXX

YY

XXX=year, month

day,

YY= hour, minute

27

Host SMS Number

Setting

49~

50

X

X= SMS number

28

Host Alarm Phone

Number Setting

51~

56

X

X=alarm number

29

Host Center Call Number

Setting

57~

58

X

X= Call number of Receiving

Center

30

GSM Signal Checking

62

X

X=#

Summary of Contents for GS-G90E

Page 1: ...lly about low power of battery 7 SMS prompt when AC power lost or recovered 8 Built in intercom horn two way communication can be realized 9 Built in wireless transmitting module could be coding with wireless siren 10 Build in wireless transmitter can control 4 relay outputs with home appliances such as lights garage door television curtain etc 11 1 group timed Arm and timed Disarm function 12 Can...

Page 2: ...ving effect from all wireless detectors Please note that keep the host away from large sized metallic objects and home appliances producing high frequency interference meanwhile avoid steel reinforced concrete and fire proof doors Panel schemes Installation drawing on the back wire connecting terminal LCD display ...

Page 3: ...tons the host emits a long beep and exits settings to main interface 4 Coding of Remote Controller Setting The remote controller has to be coded to the alarm host in order to perform normally Press firstly then input 4 digit password by the keypad on the host and input instruction code 21 Press to confirm then you will hear remote control coding the indicator is on without flashing Press any butto...

Page 4: ...efense zone number needs to be deleted finally press to confirm The host emits a long beep You will hear a voice prompt delete completed Operating method Password 24 XX XX indicates 02 99 defense zones number Example Delete 02 defense zones Operating method Password 24 02 LCD display 8 All Wireless Detector Deleting Setting The wireless detector can t trigger the host to alarm after the whole dele...

Page 5: ...of 81 wired defense zone of Z2 is equal to zone of 82 and wired defense zone of Z8 is equal to zone of 88 in turn Example alarm type about defense zone of 82 is set to out arm or home arm Operating method Password 47 82 1 LCD display 10 Wireless Equipment Coding Setting Press firstly then input 4 digit password by the keypad input instruction code 27 8 wireless equipment coding then enter to confi...

Page 6: ...t setting completed Operating method Password 33 XX XX indicates Arm delayed time unit second Example detailed operating of 2 seconds delayed time arm Operating method Password 33 02 LCD display 14 Alarm Delayed Setting Alarm time delayed setting is that the host will not alarm until delayed time arrives Press firstly then input 4 digit password by the keypad input instruction 34 enter zone number...

Page 7: ...control Operating method Password 36 2 Notes The host remote control closed when ringing times is set to 0 LCD display 17 Voice Recording message Setting Press firstly then input 4 digit password by the keypad input instruction 37 and then press to confirm The host will emits a beep and the indicator is on and after 10 second s countdown recording starts record at 30cm away from the host with mod ...

Page 8: ...t 4 digit password by the keypad input instruction 40 then input 0 1 finally press to confirmed The host makes a long beep You will hear a voice prompt setting completed Operating Password 40 X X 0 indicates Keypad lock is closed Arm Disarm password don t need to be entered X 1 indicates Keypad lock is open Arm Disarm password should be entered Example Open the keypad lock Operating Password 40 1 ...

Page 9: ...ally when main host reset Press firstly then input 4 digit password by the keypad input instruction 43 then press to confirm The host makes a long beep You will hear a voice prompt setting completed Will not delete the remote control and accessories Operating Password 43 LCD display 23 Host Historical Records Inquires Setting Press firstly then input 4 digit password by the keypad input instructio...

Page 10: ...p and a voice prompt setting completed Operating Password 48 AA BB CC DD EE AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates the 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present second Example set the time as 17 30 June 12th 2012 Operating Password 48 12 06 12 17 30 LCD ...

Page 11: ...password by the keypad input instruction 51 56 then press to confirm The host makes a long beep You will hear a voice prompt setting completed Operating Password XX XX indicates address code 51 56 of 1 6 group alarm phone number Example Delete the 1 group of alarm phone number Operating Password 51 LCD display 31 Defense Zone name Setting Press firstly then input 4 digit password by the keypad inp...

Page 12: ...l time Disarm and etc 1 Out Arm Press 2 Disarm Press 3 Home Arm Press 4 SOS Press 3 Away Arm It means to guard all around your house while everyone is going out all the det ectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press Out Arm button on keypad system will make a beep per s...

Page 13: ...rm it stops calling users Press 2 The host stops alarming and to Disarm it stops calling users Press 3 The host closes Siren and monitors the scene for 30 seconds for continuous monitoring press 3 again to monitor the abnormal sounds or a burglar intrusion for another 30 seconds Press 4 start talkback 30s Press 6 Turn on the relay NO 1 Press 6 again turn it off Press 7 Turn on the relay NO 2 Press...

Page 14: ...eration press remote control a Keypad operation press alarm host keypad 10 Alarm host used as hand free phone This alarm system has dial up function and could be used as hand free phone In disarming status input phone number 13800138000 then press main host makes a long beep then phone call will go out after Call completed press again to hang up phone 11 Maintenance 1 System detection Although the...

Page 15: ...product on the ground or hard objects to avoid strong impact for failure and damage Without permit and consent from relevant department do not directly set 110 119 or alarm phone number of police station as alarm phone number of the host Technical Parameters 1 Table one 2 Table two Technical Parameter Adaptor power DC12V 1000mA Static consumption 55mA Alarm current 450mA Output current DC12V 150mA...

Page 16: ... 14 Telephone Dial up Cycle Times 35 X X 00 09 times 9 times 15 Remote Call Ring Times 36 X X 0 9 times 9 times 16 Artificial Recording 37 X X play automatically after recording 17 Change User Password 38 XXXX XXXX 4 digit 1234 18 Change Administrator Password 39 XXXX XXXX 4 digit 6666 19 Keypad Lock Setting 40 X X 1 open X 0 closed 0 20 Host Timing Setting 41 X X 1 open time setting function X 0 ...

Reviews: