32. Host GSM Signal Checking
Press
firstly, then input 4- digit password by the keypad,input instruction
[62] and then press
to confirm. The host makes a long beep, you will hear a
voice prompt: “setting completed”. GSM signal value displays.
Operating:
Password
[62]
LCD display:
[Operation Instructions]
1. Main Host Status
System status: There are 4 status types as follows:
1) Arm:
Defense zone 02-99 will alarm when detectors are triggered
2) Home Arm:
In arm status, the defense zone which is set as [Home arm],
when detectors are triggered.
3) Disarm:
Defense zone 02-99 will not alarm when detector triggered (except
24 hours defense zone).
4) System setup status:
In this status, all defense zones will not alarm when
detectors are triggered.
2. Remote Controller Operation
U
ser can use remote controller to set system as Out Arm, Home Arm,
Emergency Alarm, Real-time Disarm and etc.
1) Out Arm:
Press [
]
2) Disarm:
Press [
]
3) Home Arm:
Press [
]
4) SOS:
Press [
]
3. Away Arm
It means to guard all around your house while everyone is going out; all the det
ectors of the host are always working; when the detector is triggered by
detecting source(anti-theft, fire prevention,gas leak, etc), the alarm system will
sound the alarm.
Press [Out Arm
] button on keypad, system will make a beep per second
and totally 100 beeps. The [Out Arm
] indicator will be on without flashing. It
means Out Arm is set successfully.
Operating: press [Out Arm
] of remote controller
The Host Operating: [Out Arm
] (keypad lock is closed or [Out
Arm
] +
[user password] +
(keypad lock is open)
LCD display:
4. Home Arm
It means, for the safety, while somebody is at home, you need to enable
the peripheral:
door, window, balcony and boundary detectors of the alarm
system while prevent from triggering the indoor detectors, which may cause
improper warning; then, you shall select Home Arm, let just part of the detectors
work and disable the other parts.
Alarm host operation: Press