Lightinthebox GS-G90E Instruction Manual Download Page 1

Contents

目录

Preface]

Thank you for choosing the wireless alarm system product of our company.

Wireless alarm system adopts the most advanced digital sensing and

controlling technologies, it is the intelligent alarm control system containing burglar

alarm, fire alarm, fire fighting, gas leakage and SOS.

Wireless alarm system uses the most advanced multiple random selection

technology, it avoids the problems of interference and alarm missing which usually

exist in the similar systems. This system can be used widely in residence, shops,

villa, and small enterprise and so on.

For your safety, before installing and using, we suggest you read this manual

carefully.

Caution

To ensure that you can enjoy the impeccable warranty service, do not

open the host-housing to repair and renovation by yourself or we will not provide

free warranty service. All the losses and the adverse consequences it makes will be

assumed by users.

Please make safekeeping to the user manual for reference when it is

necessary.

[Function Introduction]

1.

Touch screen keypad GSM alarm system

2.

8 Wired defense zones and 100 wireless defense zones.

3.

At most 5 wireless remote control codes.

4.

Touch keypad

Built-in clock.

LCD display. Operate easily.

5.

Voice prompt for each operation.

6.

SMS prompt automatically about low power of battery.

7.

SMS prompt when AC power lost or recovered.

8.

Built-in intercom horn, two way communication can be realized.

9.

Built-in wireless transmitting module, could be coding with wireless siren.

10. Build-in wireless transmitter,can control 4 relay outputs with home

appliances,such as lights,garage door,television,curtain,etc.

11. 1 group timed Arm and timed Disarm function.
12. Can store 6 groups of phone numbers: when alarming, system will make

alarm call to these numbers automatically.

13. Can store 2 groups of SMS numbers: when alarming, system will send

alarming SMS to these numbers automatically.

14. Can store 2 alarm center telephones.
15. Inquire the status of alarm panel by SMS.
16. Delay alarming for each defense zone(0-99 seconds)
17. 10-second voice message recording can be played automatically when

alarming.

18. The host can be used as a hand-free phone. Users can make call by the

keypad for telephone fee inquiry and charging.

19. One-key-control function: Out Arm, Home Arm, Remote Arm.
20. Real-time, delay, 24 hours, bypass defense zones programming function.
21. Wireless coding: easy to add additional wireless accessories.
22. Remote control Arm, Disarm, Monitor, and Intercom by phone.
23. Event Log Query: host automatically records 40 pieces of all information

concerning arm, disarm and alarm events.

24. Multi-type of arm: Remote control arm, out arm, home arm, timed arm, arm

by phone.

25. Built-in AAA NI-MH rechargeable battery: make alarm when power off.

Summary of Contents for GS-G90E

Page 1: ...lly about low power of battery 7 SMS prompt when AC power lost or recovered 8 Built in intercom horn two way communication can be realized 9 Built in wireless transmitting module could be coding with wireless siren 10 Build in wireless transmitter can control 4 relay outputs with home appliances such as lights garage door television curtain etc 11 1 group timed Arm and timed Disarm function 12 Can...

Page 2: ...ving effect from all wireless detectors Please note that keep the host away from large sized metallic objects and home appliances producing high frequency interference meanwhile avoid steel reinforced concrete and fire proof doors Panel schemes Installation drawing on the back wire connecting terminal LCD display ...

Page 3: ...tons the host emits a long beep and exits settings to main interface 4 Coding of Remote Controller Setting The remote controller has to be coded to the alarm host in order to perform normally Press firstly then input 4 digit password by the keypad on the host and input instruction code 21 Press to confirm then you will hear remote control coding the indicator is on without flashing Press any butto...

Page 4: ...efense zone number needs to be deleted finally press to confirm The host emits a long beep You will hear a voice prompt delete completed Operating method Password 24 XX XX indicates 02 99 defense zones number Example Delete 02 defense zones Operating method Password 24 02 LCD display 8 All Wireless Detector Deleting Setting The wireless detector can t trigger the host to alarm after the whole dele...

Page 5: ...of 81 wired defense zone of Z2 is equal to zone of 82 and wired defense zone of Z8 is equal to zone of 88 in turn Example alarm type about defense zone of 82 is set to out arm or home arm Operating method Password 47 82 1 LCD display 10 Wireless Equipment Coding Setting Press firstly then input 4 digit password by the keypad input instruction code 27 8 wireless equipment coding then enter to confi...

Page 6: ...t setting completed Operating method Password 33 XX XX indicates Arm delayed time unit second Example detailed operating of 2 seconds delayed time arm Operating method Password 33 02 LCD display 14 Alarm Delayed Setting Alarm time delayed setting is that the host will not alarm until delayed time arrives Press firstly then input 4 digit password by the keypad input instruction 34 enter zone number...

Page 7: ...control Operating method Password 36 2 Notes The host remote control closed when ringing times is set to 0 LCD display 17 Voice Recording message Setting Press firstly then input 4 digit password by the keypad input instruction 37 and then press to confirm The host will emits a beep and the indicator is on and after 10 second s countdown recording starts record at 30cm away from the host with mod ...

Page 8: ...t 4 digit password by the keypad input instruction 40 then input 0 1 finally press to confirmed The host makes a long beep You will hear a voice prompt setting completed Operating Password 40 X X 0 indicates Keypad lock is closed Arm Disarm password don t need to be entered X 1 indicates Keypad lock is open Arm Disarm password should be entered Example Open the keypad lock Operating Password 40 1 ...

Page 9: ...ally when main host reset Press firstly then input 4 digit password by the keypad input instruction 43 then press to confirm The host makes a long beep You will hear a voice prompt setting completed Will not delete the remote control and accessories Operating Password 43 LCD display 23 Host Historical Records Inquires Setting Press firstly then input 4 digit password by the keypad input instructio...

Page 10: ...p and a voice prompt setting completed Operating Password 48 AA BB CC DD EE AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates the 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present second Example set the time as 17 30 June 12th 2012 Operating Password 48 12 06 12 17 30 LCD ...

Page 11: ...password by the keypad input instruction 51 56 then press to confirm The host makes a long beep You will hear a voice prompt setting completed Operating Password XX XX indicates address code 51 56 of 1 6 group alarm phone number Example Delete the 1 group of alarm phone number Operating Password 51 LCD display 31 Defense Zone name Setting Press firstly then input 4 digit password by the keypad inp...

Page 12: ...l time Disarm and etc 1 Out Arm Press 2 Disarm Press 3 Home Arm Press 4 SOS Press 3 Away Arm It means to guard all around your house while everyone is going out all the det ectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press Out Arm button on keypad system will make a beep per s...

Page 13: ...rm it stops calling users Press 2 The host stops alarming and to Disarm it stops calling users Press 3 The host closes Siren and monitors the scene for 30 seconds for continuous monitoring press 3 again to monitor the abnormal sounds or a burglar intrusion for another 30 seconds Press 4 start talkback 30s Press 6 Turn on the relay NO 1 Press 6 again turn it off Press 7 Turn on the relay NO 2 Press...

Page 14: ...eration press remote control a Keypad operation press alarm host keypad 10 Alarm host used as hand free phone This alarm system has dial up function and could be used as hand free phone In disarming status input phone number 13800138000 then press main host makes a long beep then phone call will go out after Call completed press again to hang up phone 11 Maintenance 1 System detection Although the...

Page 15: ...product on the ground or hard objects to avoid strong impact for failure and damage Without permit and consent from relevant department do not directly set 110 119 or alarm phone number of police station as alarm phone number of the host Technical Parameters 1 Table one 2 Table two Technical Parameter Adaptor power DC12V 1000mA Static consumption 55mA Alarm current 450mA Output current DC12V 150mA...

Page 16: ... 14 Telephone Dial up Cycle Times 35 X X 00 09 times 9 times 15 Remote Call Ring Times 36 X X 0 9 times 9 times 16 Artificial Recording 37 X X play automatically after recording 17 Change User Password 38 XXXX XXXX 4 digit 1234 18 Change Administrator Password 39 XXXX XXXX 4 digit 6666 19 Keypad Lock Setting 40 X X 1 open X 0 closed 0 20 Host Timing Setting 41 X X 1 open time setting function X 0 ...

Reviews: