11
▲
first set speed at lowest position.
▲
second check the belt shifts to which side.
If the belt shifts to right, tighten the right bolt and loosen the left bolt by using 6mm Hexagonal
Wrench, until the belt is centered itself; If belt shifts to left, tighten the left bolt and loosen the right bolt
by using 6mm Hexagonal Wrench, until the belt is centered. When adjusting the belt using the 6 mm
Hexagonal Wrenches, it is important to adjust the belt in half turn increments. Over adjusting the belt can
cause damage to the mat.
8. Solutions for Failure Elimination
Failure
Possible Reason
Solution
The power supply is
connected and the electric
running machine has
started, however, there is no
any display.
1
.
The socket and
power supply is
not connected
well.
2
.
The socket of
electric motor is
not connected
well.
3
.
The fuse is
burned.
1
.
Insert the socket again.
2
.
Re-connect the socket.
3
.
Disconnect the power
supply and replace the
fuse.
All displays fail to work.
Keys are installed
improperly in
emergency.
Perfect the installation.
Operation stops
automatically and E1 is
displayed.
The
self-maintenance
function of system
works suddenly.
1
.
Restart the electric
running machine after
pressing ‘STOP’.
2
.
Restart the electric
running machine after
the power supply has
been disconnected for
5min.
3
.
Replace the sensor.
Display shows a normal
operation, the strap,
however, operates
improperly and suffers from
a cacophony.
The input voltage is
too low.
The input power should
meet the requirement.
The electric running
machine operates normally
with no load but halts
midway.
The strap becomes
loose.
Adjust the strap following
the specification.
The display fails to work or
cannot display at all, and the
keys don’t work.
The electronic meter
is influenced by an
external factor.
Disconnect the power
supply and switch off
switches, and restart the
electric running machine
5min later.
Summary of Contents for BOOMER PLUS