background image

Manual 0940-7217-01 Rev.A

ATTENTION: Please take a few minutes to thoroughly read this
user guide which should be saved for future reference and passed
on to any subsequent owner.

Smoke Alarm 

User Guide

i9040EU

• 9 Volt Battery Operated       

Model:  

i9040EU

EN14604: 2005

LPCB Ref No. 904a/06

0832-CPD-1427

0940-7217-01_V1.qxd:_  2013.7.1  4:17 PM  Page 1

Summary of Contents for i9040EU

Page 1: ...ughly read this user guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User Guide i9040EU 9 Volt Battery Operated Model i9040EU EN14604 2005 LPCB Ref N...

Page 2: ...th all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any i...

Page 3: ...EFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTION DUE TO THE LOUDNESS OF THE ALARM 85 DECIBELS ALWAYS STAND AN ARMS LENGTH AWAY FROM THE UNIT WHEN TESTING CAUTION BEFORE USING THE ALARM HUSH...

Page 4: ...using the ionisation technique It contains 0 9 microcurie of Americium 241 a radioactive material see section 9 Do not try to repair the smoke alarm yourself Refer to the instructions in section 11 fo...

Page 5: ...the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room...

Page 6: ...e 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling within 30 5cm vertically down from the highest point se...

Page 7: ...within 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other...

Page 8: ...ons FIGURE 5 A A FIGURE 6 FIGURE 7 FIGURE 8 mounting bracket The A line should be horizontal and the UP FOR WALL MOUNTING arrow must be pointing up Alignment marks Install Remove 0940 7217 01_V1 qxd _...

Page 9: ...mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper installation of the smoke alarm battery follow t...

Page 10: ...n and will flash every 40 seconds to indicate that the smoke alarm is receiving power TESTING Test by pushing the test button on the cover and holding it down for a minimum of 5 seconds This will soun...

Page 11: ...PLACEMENT Alkaline type ENERGIZER 522 DURACELL MN1604 MX1604 GOLD PEAK 1604A NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIF FERENT BATTERIES MAY HAVE A DETRIMENTAL...

Page 12: ...commends that both Ionisation and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without...

Page 13: ...n every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all sleeping individua...

Page 14: ...l 3 On every level of a dwelling unit including basements 4 On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics...

Page 15: ...date of purchase or if it fails to operate due to improper maintenance or inadequate A C or D C electrical power THE LIABILITY OF KSE LIMITED OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING F...

Page 16: ...l our Consumer Hotline UK 0800 917 0722 Ireland 1 800 818 601 Lifesaver is a brand of Kidde Safety Europe Limited Kidde Safety Europe Ltd Mathisen Way Poyle Road Colnbrook Berkshire SL3 0HB 0940 7217...

Reviews: