10 Year Photoelectric Smoke Alarm
Year Photo
Model number:
54866
Thank you for purchasing our smoke alarm. Please take a
few minutes to read the user’s manual thoroughly and
familiarize yourself and your family with its operation. And
save it for future reference.
Diagram 1
Product Specifications:
POWER
: built-in DC3V(CR-2/3AZ) Lithium battery
(battery not replaceable)
OPERATION CURRENT
:
<8uA (standby), <70mA
(alarm)
ALARM VOLUME
: >85 dB (A) at 3 meters.
ALARM SENSITIVITY
: 1.6-2.74%/ft OBS
SILENCE TIME: a
pprox. 10 minutes
SMOKE ALARM SOUND PATTERN
:
Temporal 3
BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s –
pause 1.5s, with the red LED flash, repeat this alarm
pattern.
COMPLY WITH:
UL217 &CAN/ ULC-S531
Description:
This unit is a photoelectric smoke alarm. The photoelectric
technology, it is more sensitive in detecting slow smoldering
fires which generate light smoke, little heat and may smolder
for hours before bursting into flames. This smoke alarm does
not contain any radioactive material. Smoke alarms should be
installed in every room (except the bathroom and kitchen),
finished attics and basements, making sure the people in the
home will be able to hear and respond to the alarm sound.
For minimum protection, you should install an alarm on
every level of the home particularly outside sleeping rooms.
Each alarm should be placed in the middle of the ceiling of
each room to be protected. Typical single storey dwelling
installation recommendations: Install a smoke alarm on the
ceiling or wall inside each bedroom and in the hallway
outside each separate sleeping area. If a bedroom area
hallway is more than 30 feet long, install a smoke alarm at
each end. If there is a basement: install a smoke alarm on the
basement ceiling at the bottom of the stairwell. Typical
multi-storey dwelling installation recommendations: Install a
minimum of one smoke alarm on each occupiable level of the
home. Install a smoke alarm on the ceiling or wall inside
each bedroom and in the hallway outside each separate
sleeping area. If a bedroom area hallway is more than 30 feet
long, install a smoke alarm at each end install a smoke alarm
at the top of a first – to- second floor stairwell.
Important Safety Information:
1.
The test button accurately tests smoke alarm functions. Do
not use any other test method. Test smoke alarm weekly to
ensure proper operation.
2.
If you're sure it isn't a really alarm, open windows or fan
the air around smoke alarm to test and silence it.
3.
User to install this product needs to comply with all local
and national electrical installation and building codes.