10 Year Photoelectric Smoke Alarm

 Year Photo

Model number: 

54866

Thank you for purchasing our smoke alarm. Please take a 
few minutes to read the user’s manual thoroughly and 
familiarize yourself and your family with its operation. And 
save it for future reference.  

 

Diagram 1

 

Product Specifications:

 

POWER

:  built-in  DC3V(CR-2/3AZ)  Lithium  battery

 

(battery not replaceable)

OPERATION  CURRENT

:

<8uA  (standby),  <70mA

 

(alarm)

ALARM VOLUME

: >85 dB (A) at 3 meters.

ALARM SENSITIVITY

: 1.6-2.74%/ft OBS

SILENCE TIME: a

pprox. 10 minutes

SMOKE ALARM SOUND PATTERN

Temporal 3

 

BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s –

pause  1.5s,  with  the  red  LED  flash,  repeat  this  alarm

 

pattern.

COMPLY WITH:

 UL217 &CAN/ ULC-S531 

Description:

This  unit  is  a  photoelectric  smoke  alarm.  The  photoelectric 

technology, it is more sensitive in detecting slow smoldering 

fires which generate light smoke, little heat and may smolder 

for hours before bursting into flames. This smoke alarm does 

not contain any radioactive material. Smoke alarms should be 

installed  in  every  room  (except  the  bathroom  and  kitchen),   

finished attics and basements, making sure the people in the 

home  will  be  able  to  hear  and  respond  to  the  alarm  sound. 

For  minimum  protection,  you  should  install  an  alarm  on 

every level of the home particularly outside sleeping rooms.  

Each alarm should be placed in the middle of the ceiling of 

each  room  to  be  protected.  Typical  single  storey  dwelling 

installation  recommendations:  Install  a  smoke  alarm  on  the 

ceiling  or  wall  inside  each  bedroom  and  in  the  hallway 

outside each separate sleeping area. If a bedroom area 

 

hallway  is  more  than  30  feet  long,  install  a  smoke  alarm  at 

each end. If there is a basement: install a smoke alarm on the 

basement  ceiling  at  the  bottom  of  the  stairwell.  Typical 

multi-storey dwelling installation recommendations: Install a 

minimum of one smoke alarm on each occupiable level of the 

home.  Install  a  smoke  alarm  on  the  ceiling  or  wall  inside 

each  bedroom  and  in  the  hallway  outside  each  separate 

sleeping area. If a bedroom area hallway is more than 30 feet 

long, install a smoke alarm at each end install a smoke alarm 

at the top of a first – to- second floor stairwell.

 

Important Safety Information:

 

1.

 

The test button accurately tests smoke alarm functions. Do

not use any other test method. Test smoke alarm weekly to

ensure proper operation.

2.

 

If  you're  sure  it  isn't  a  really  alarm,  open  windows  or  fan

the air around smoke alarm to test and silence it.

3.

 

User to install this product needs to comply with all local

and national electrical installation and building codes.

800.607.054

1  

|

  31100 Solon Rd STE 16 Solon, OH 44139

Summary of Contents for 54866

Page 1: ...hould install an alarm on every level of the home particularly outside sleeping rooms Each alarm should be placed in the middle of the ceiling of each room to be protected Typical single storey dwelling installation recommendations Install a smoke alarm on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet l...

Page 2: ...ing explosive or intentional and others are caused by carelessness or safety hazards In such circumstances Smoke may not reach the alarm QUICKLY ENOUGH to ensure safe escape Therefore the installation of smoke alarms is not a substitute for practicing fire safety in the home 8 Smoke alarms have limitations This smoke alarm is not foolproof and is not warranted to protect lives or property from fir...

Page 3: ...ce the trouble indication for 10 hours but it will reset automatically after 10 hours During this condition the unit will continue to operate normally and detect smoke and sound an alarm This action only temporarily silences the chirp NOTE As the battery in this unit is not replaceable a low battery signal is an indication of end of life Therefore the alarm MUST be replaced as soon as possible Fau...

Page 4: ...essing the test button temporarily silence this warning tone for 10 hours it will again prompt you to replace the alarm after 10 hours Maintenance and Cleaning In addition to weekly testing the alarm requires periodic cleaning to remove dust dirt and debris Clean the alarm at least once a year to remove dust dirt or debris Use a vacuum cleaner with a soft brush vacuum all sides and covers of smoke...

Page 5: ...can return to your retailer 4 if the unit is out of warranty please replace another new alarm An intermittent chirp accompanied by a red LED flash The battery is depleted please replace the smoke alarm every 40 seconds Smoke alarm chirp occurs every 40 seconds only alarm goes into fault mode Clean smoke alarm Please refer to the maintenance and cleaning section Replace smoke alarm if the problem p...

Page 6: ...east one alarm on every floor level Locate an alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent an alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread ...

Page 7: ... the ceiling In such units install the smoke alarm on an inside wall with the top edge of the alarm at a minimum of 4 10cm and a maximum of 12 30 5cm below the ceiling see Diagram 2 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either hot or cold install the alarm on an inside wall For minimum protection install at least one alar...

Page 8: ...the Recommended Locations mark installation holes of the bracket with pencil Drill the two marked installation holes with a 3 16 inch 5mm drill bit Tap the two plastic grommets into holes with hammer Remove locking plug from the bracket with screwdriver if necessary Refer to Diagram 6 This is an optional additional locking in place feature Mount the bracket to the ceiling by inserting and tighteni...

Page 9: ...ed if no sound it indicates a defective alarm refer to the Trouble shooting section for a solution or return to your retailer during warranty WARNING To prevent injury this unit must be securely attached to the wall or ceiling in accordance with the installation instructions Diagram 7 Diagram 6 800 607 0541 31100 Solon Rd STE 16 Solon OH 44139 ...

Page 10: ...austed Must also allow the battery to fully discharge for at least one day 2 Use this method to scrap the alarm if the is the end of life during out of warranty 3 Please return to retailer and change another alarm during the Warranty 4 Cannot install the smoke alarm again once he battery is discharged Diagram 9 SERVICE AND WARRANTY Company warrants to the original consumer Purchase each new smoke ...