1. Recommended Locations for Smoke Alarms

• Put smoke alarms at both ends of a hallway or large room if the

hallway or room is more than 9.1 m long.  For large rooms, one
smoke alarm is recommended for every 47 square meters of floor
space.

• In homes that are not well insulated, extreme heat or cold can be

transferred from the outside to the inside through poorly insulated
walls and roof. This may create a thermal barrier which can prevent
the smoke from reaching an alarm mounted on the ceiling.  If you are
not sure about the insulation in your home, or if you notice that the
outer walls and ceiling are either hot or cold, install the alarm on an
inside wall. In such homes, install the smoke alarm with the top edge
of the alarm at a minimum 10 cm and a maximum of 30.5 cm below
the ceiling (see figure 1).

• Install Smoke Alarms on sloped, peaked or cathedral ceilings at or

within 0.9m of the highest point (measured horizontally).   Smoke
alarms in rooms with ceiling slopes greater than 0.3m in 2.4 m 
horizontally shall be located on the high side of the room. A row of
detectors shall be spaced and located within 0.9m of the peak of the
ceiling measured horizontally  (see figure 2).

• Install Smoke Alarms on tray-shaped ceilings (coffered ceilings) on the

highest portion of the ceiling or on the sloped portion of the ceiling
within 30.5cm) vertically down from the highest point (see figure 4).

Mobile Home Installation

Modern mobile homes have been designed and built to be energy effi-
cient. Install smoke alarms as recommended above (refer to RECOM-
MENDED LOCATIONS and Figures 1 and 2). In older mobile homes that
are not well insulated compared to present standards, extreme heat or
cold can be transferred from the outside to the inside through poorly
insulated walls and roof. This may create a thermal barrier which can
prevent the smoke from reaching an alarm mounted on the ceiling. In
such units, install the smoke alarm on an inside wall with the top edge
of the alarm at a minimum of 10cm and a maximum of 30.5cm below
the ceiling (see figure 1).

If you are not sure about the insulation in your mobile home, or if you
notice that the outer walls and ceiling are either hot or cold, install the
alarm on an inside wall. For minimum protection, install at least one
alarm close to the sleeping rooms. For additional protection, see SINGLE
FLOOR PLAN in figure 2.

WARNING: TEST YOUR SMOKE ALARM OPERATION AFTER RV

OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE, BEFORE
EACH TRIP AND AT LEAST ONCE A WEEK DURING USE.

!

0940-7217-01_V1.qxd:_  2013.7.1  4:18 PM  Page 6

Summary of Contents for i9040EU

Page 1: ...ughly read this user guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User Guide i9040EU 9 Volt Battery Operated Model i9040EU EN14604 2005 LPCB Ref N...

Page 2: ...th all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open any i...

Page 3: ...EFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTION DUE TO THE LOUDNESS OF THE ALARM 85 DECIBELS ALWAYS STAND AN ARMS LENGTH AWAY FROM THE UNIT WHEN TESTING CAUTION BEFORE USING THE ALARM HUSH...

Page 4: ...using the ionisation technique It contains 0 9 microcurie of Americium 241 a radioactive material see section 9 Do not try to repair the smoke alarm yourself Refer to the instructions in section 11 fo...

Page 5: ...the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the room places it closest to all points in the room...

Page 6: ...e 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling within 30 5cm vertically down from the highest point se...

Page 7: ...within 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other...

Page 8: ...ons FIGURE 5 A A FIGURE 6 FIGURE 7 FIGURE 8 mounting bracket The A line should be horizontal and the UP FOR WALL MOUNTING arrow must be pointing up Alignment marks Install Remove 0940 7217 01_V1 qxd _...

Page 9: ...mounting plate use 3 16 drill bit for anchor holes 4 Battery installation instructions are provided on the inside of the battery door To ensure proper installation of the smoke alarm battery follow t...

Page 10: ...n and will flash every 40 seconds to indicate that the smoke alarm is receiving power TESTING Test by pushing the test button on the cover and holding it down for a minimum of 5 seconds This will soun...

Page 11: ...PLACEMENT Alkaline type ENERGIZER 522 DURACELL MN1604 MX1604 GOLD PEAK 1604A NOTE WEEKLY TESTING IS REQUIRED WARNING USE ONLY THE BATTERIES SPECIFIED USE OF DIF FERENT BATTERIES MAY HAVE A DETRIMENTAL...

Page 12: ...commends that both Ionisation and Photoelectric alarms be installed A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without...

Page 13: ...n every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prior to an emergency Current studies have shown smoke alarms may not awaken all sleeping individua...

Page 14: ...l 3 On every level of a dwelling unit including basements 4 On every level of a residential board and care occupancy small facility including basements and excluding crawl spaces and unfinished attics...

Page 15: ...date of purchase or if it fails to operate due to improper maintenance or inadequate A C or D C electrical power THE LIABILITY OF KSE LIMITED OR ANY OF ITS PARENT OR SUBSIDIARY CORPORATIONS ARISING F...

Page 16: ...l our Consumer Hotline UK 0800 917 0722 Ireland 1 800 818 601 Lifesaver is a brand of Kidde Safety Europe Limited Kidde Safety Europe Ltd Mathisen Way Poyle Road Colnbrook Berkshire SL3 0HB 0940 7217...

Reviews: