LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 165
Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with its own plans
and specifications and to be free from defects in materials and workmanship under normal use and
service for 24 months from the date stamp control on the product(s) or, for product(s) not having a
manufacturer’s date stamp, for 12 months from date of original purchase unless the installation
instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's
obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any
product(s) which is proved not in compliance with Seller's specifications or proves defective in materials
or workmanship under normal use and service. Seller shall have no obligation under this Limited
Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than
Honeywell factory service. For warranty service, return product(s) transportation prepaid, to Honeywell
Factory Service, 165 Eileen Way, Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR
A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON
THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY
CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER
WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER,
EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT.
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the
product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that
the product(s) will in all cases provide adequate warning or protection. Customer understands that a
properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire
,
or
other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not
occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER
SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS
BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER
IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING
UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN,
SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF
THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST
SELLER.
This warranty replaces any previous warranties and is the only warranty made by Seller on this
product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is
authorized.
FCC STATEMENT
FCC ID: CFS8DL5806 Canada: 1748-K1430
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference (2) This device must accept any interference
received, including interference that may cause undesired operation.
165 Eileen Way, Syosset, New York 11791
Copyright © 2004 Honeywell International Inc.
www.honeywell.com/security
ÊN6353V5mŠ
N6353V5 7/04 Rev A
N6353V5 7/04 Rev A
ADEMCO 5806
Smoke Detector With Built-In
Wireless Transmitter
INSTALLATION INSTRUCTIONS
General Information
The ADEMCO 5806 Photoelectric Smoke
Detector/Transmitter is intended for use with
wireless alarm systems that support 5800
Series devices, and contains a built-in
transmitter that can send alarm, supervisory
and battery condition messages to the
system's receiver/control unit. Refer to the
wireless system's instructions for the
maximum number of transmitters that can be
supported.
Alarms:
The smoke detector is powered by
two 9-volt batteries and will sound its built-in
horn when smoke reaches the detector (the
LED indicator will also flash rapidly). A
message will also be sent to the wireless
control and the smoke detector's ID number
will be displayed at the keypad. The alarm
message will be transmitted every 4
seconds, until the smoke condition has
cleared and the detector has reset. About 1
second after the horn has stopped, a Restore
message will be transmitted to the control
and it will then be possible to clear the ID
number from the display. During normal or
low battery conditions, the LED indicator will
flash about once every 40 seconds.
Low Battery:
The detector indicates a low-
battery condition by emitting a "chirp" about
once every 40 seconds. A low-battery
message will be sent to the control unit upon
any transmission following the first battery
chirp (with the detector's ID number displayed
at the keypad). The battery should be replaced
within 30 days following the low-battery
signals.
False Alarm Protection:
In order to reduce
the possibility of false alarms due to cigarette
smoke, dust, steam, insects, etc., the detector
will not transmit an alarm signal until its horn
has sounded continuously for about 6
seconds. A delay also occurs when the
detector is tested. Therefore, the test button
must be held down for about 20 seconds
before the horn will sound. The first alarm
signal will be transmitted within 6 seconds
after the horn sounds.
Programming:
Note that the control system
must “enroll” the smoke detector’s ID during
installation of the system. The control should
be programmed to “enroll” the 5806 as an “RF”
type unit (i.e., supervised RF). See the
PROGRAMMING section in this instruction
book and the control unit’s Installation
Instructions for further details.
Tamper Protection:
The detector has
provision for a tamper function if desired.
When the tamper function, is enabled, the
detector will cause a CHECK to be displayed if
it is removed from its installed location. See
TAMPER PROTECTION for detailed
instructions.
Battery Installation and
Replacement
TO REMOVE
TO SECURE
INDICATOR LIGHT.
FLASHES ONCE
EVERY 40 SECS
DURING NORMAL
OPERATION
TEST BUTTON
SENSING
CHAMBER
OPENINGS
The 5806 is equipped with two 9-volt batteries,
which can double the time between battery
replacement (compared to a single 9-volt
alkaline battery). Refer to the
SPECIFICATIONS section for acceptable
batteries. The batteries should be changed
within 30 days following the low battery beeps
(about once every 40 seconds). There will
also be a low-battery display on the system’s
keypad. Be sure to replace BOTH batteries
with fresh ones.
Important: