1.The machine is in
deicing condition
1.This state is deicing state, it
will change according to the
different ambient temperature.
The longest time is 3.5
minutes. After deicing, the
machine will automatically turn
into the normal ice making
state.
1.Remove the ice that is
pressed on the white flap and
the machine will reset itself
automatically
2.Manually reset, or replace
the white flap
1.Check the pressure of inlet
water (100KPa-600KPa, no
less than 100KPa)
2.Check whether the water
level switch floats, check
whether there is something
stuck it, manually reset
several times and then restart
the machine
Troubleshooting method of fan
˜
1. Turn on the power for 10 seconds and enter the standby
state. At this time, click on the "on/off" button and the fan will start to balance the temperature in
the cabin for 1 minute.Observe the air inlet at the front of the machine in this 1-minute stage. If
there is no wind, it will be regarded as fan failure.
Troubleshooting method of water pump
˜
Add water. Turn on the power for 10 seconds and
enter the standby state. At this time, click the cleaning button, visually check whether the pump
is started, whether there is water flowing out of the water pipe. if there is no water flowing out, it
is considered as pump failure.
1.There is no water in
the machine
2.Water level switch
not reset, stuck by ice
or something else
1.The machine was
indeed filled with ice
2.The white flap is
blocked and cannot
flip properly
4
5
6
"00"
Red "Full"
light
keeps on
Red
"Water"
light
keeps on
- 25 -
TROUBLESHOOTING
ERROR CODE
1.The lead wire of the
temperature sensor is
loose
2.Temperature sensor
failure
1.Press the cleaning button for
5 seconds.
2.Contact seller to replace it.
1. The ice did not fall
from the ice tray.
2. The ice is too small.
3. The compressor or
cooling fan is damaged
(there is no sound of
fan startup when the
ice machine is turned
on)
1. Turn off the ice maker
and let the ice on the ice
tray melt naturally or remove
it manually.
2. Increase the ice making
time to increase the ice
thickness.
3. Check whether the fan
and water pump are started.
If not, contact the seller for
replacement.
1. The working
temperature of the ice
maker is too high due
to the failure of heat
dissipation.
1
2
3
"E1"
"E2"
"E4"
DBJ-45 error code and troubleshoot
No.
Error
code
Display status
Cause of failure
Troubleshooting
1. Check the surrounding of
the machine, and there shall
be no obstruction at the
cooling port. Try to put the ice
maker in an open place to
make ice to see if the fault can
be solved.
2. Check whether the cooling
fan is started. If the fan does
not start, contact the seller for
replacement.