H
SI
L
G
N
E
TECHNICAL FEATURES
LIFE home integration
reserves the right to make changes to technical characteristics at any time and without prior notice, without changing its intended
use and function.
ACER
: Irreversible electromechanical operator for sliding gates with optical/magnetic encoder and built-in ECU
Version:
ECU – 230 V ac 50 Hz
ECU – 24 V dc
AC4 / AC4R AC6 / AC6R AC8 AC4 24 P AC6 24 X AC8 24 X
Built-in ECU
RG1A / RG1R RG1A / RG1R RG1A RG1 24 P RG1A 24 X RG1A 24 X
Power supply
V
230 Vac 50 Hz
Motor power supply
V
230 V a.c. 24 V d.c.
Motor power
W
250 280
300
40
80
90
Power input from mains 230V / Max. motor absorption at pick-up 24 V A
1,1 1,2
1,4
5
6
12
Capacitor
µF 14 14
16
NO
Thrust
N
500 700
900
300
500
700
Lubrication
Tipo grease
oil
grease
oil
Thermal protection device °C
140
NO
Limit switch
2 electromechanical or magnetic limit switches in M version
Encoder
optical
magnetic
optical
Speed
m/min 10
11
External toothed wheel module
4
Number of teeth external toothed wheel
20 16
Work cycle
%
35 80
Nominal work time
min
10 20
Battery recharge time (optional)*
BATTERY NOT PROVIDED 48
Opening cycles with charged battery*
BATTERY NOT PROVIDED 20
15
10
Operating temperature °C
from -20 a +70
Protection class
IP
54
Motor insulation class
F D
Assembly
horizontal with dedicated anchorage plate
Dimensions / weight
170 (plate) x 342 x 288 (h) mm / 10 kg
Use in acid, saline or potentially explosive environment
no
Max gate weight
kg
400 600
800
400
600
800
* for 2 Ah batteries (optional and installed in control unit).
1.0 INSTALLATION
1.1
Operator release
Attention:
• The fitter must permanently fix the label describing the manual release operation close to the manual release key.
• T
he activation of the manual release could cause an uncontrolled movement of the gate in the event of mechanical damage or unbalanced conditions.
• Before performing the manoeuvre switch off the electricity supply to the automation.
• To avoid breaking the key,
do
not apply excessive force.
a) Slide the lock protection cover
(1)
. See
fig. (1.1)
.
b) Insert the key
(2)
in the lock and turn to the right through 90°.See
fig. (1.2)
.
c) Gently pull the key outwards until
the hatch is protruding, then pull outwards until it stops. See fig.
(1.3)
.
d) T
he operator is now free and can be moved by hand. A microswitch assembled on the blockage device prevents the motor from operating when
the power comes back on.
e) To reconnect the transmission, turn the opposite way and move the gate manually until it hitches up.
Figur
e
(1)
AC017
3
2
1
Fig.1.2
Fig.1.1
Fig.1.3