background image

H

SI

L

G

N

E

TECHNICAL FEATURES

LIFE home integration

 reserves the right to make changes to technical characteristics at any time and without prior notice, without changing its intended 

use and function.  

ACER

: Irreversible electromechanical operator for sliding gates with optical/magnetic encoder and built-in ECU

Version:

ECU – 230 V ac 50 Hz

ECU – 24 V dc

AC4 / AC4R           AC6 / AC6R            AC8        AC4 24 P     AC6 24 X     AC8 24 X

Built-in ECU

                                                                                                       RG1A / RG1R        RG1A / RG1R        RG1A       RG1 24 P   RG1A 24 X   RG1A 24 X

Power supply

                                                                                          V

                                           230 Vac 50 Hz

Motor power supply

                                                                                          V

                     230 V a.c.                                                24 V d.c.

Motor power

                                                                                          W

             250                        280

      300

      40

      80

        90

Power input from mains 230V / Max. motor absorption at pick-up 24 V                   A

             1,1                        1,2

      1,4

       5

       6

        12

Capacitor

                                                                                          µF                   14                         14

       16

                         NO

Thrust

                                                                                                              N

    500                       700

      900

      300

     500

       700

Lubrication

                                                                                        Tipo                               grease 

                           oil 

   grease 

oil

Thermal protection device                                                                                         °C

              140

                                                                 NO

Limit switch

2 electromechanical or magnetic limit switches in M version

Encoder

optical

magnetic

optical

Speed

                                                                                                          m/min                                 10

                                                                  11 

External toothed wheel module

          4

Number of teeth external toothed wheel

                                                                                                                20                                                                   16

Work cycle

                                                                                         %

                                35                                                                   80

Nominal work time

                                                                    min

                                10                                                                   20

Battery recharge time (optional)*

BATTERY NOT PROVIDED                                               48

Opening cycles with charged battery*

BATTERY NOT PROVIDED                            20

      15

       10

Operating temperature                                                                                          °C

from -20 a +70

Protection class

                                                                                          IP

                                                          54

Motor insulation class

                                                                                                                     F                                                                   D

Assembly

horizontal with dedicated anchorage plate

Dimensions / weight

170 (plate) x 342 x 288 (h) mm / 10 kg

Use in acid, saline or potentially explosive environment

                                                                                                     no

Max gate weight

                                                                                          kg

           400                      600

     800

       400

      600

       800

* for 2 Ah batteries (optional and installed in control unit). 

1.0  INSTALLATION

1.1 

Operator release

Attention:

•  The fitter must permanently fix the label describing the manual release operation close to the manual release key.

•  T

he activation of the manual release could cause an uncontrolled movement of the gate in the event of mechanical damage or unbalanced conditions.

•  Before performing the manoeuvre switch off the electricity supply to the automation.

•  To avoid breaking the key, 

do

 not apply excessive force.

a)  Slide the lock protection cover 

(1)

. See 

fig. (1.1)

.

b)  Insert the key 

(2)

 in the lock and turn to the right through 90°.See 

fig. (1.2)

.

c)  Gently pull the key outwards until 

the hatch is protruding, then pull outwards until it stops. See fig. 

(1.3)

.

d)  T

he operator is now free and can be moved by hand. A microswitch assembled on the blockage device prevents the motor from operating when 

 

the power comes back on.

e)  To reconnect the transmission, turn the opposite way and move the gate manually until it hitches up.

Figur

e

 (1)

AC017

3

2

1

Fig.1.2

Fig.1.1

Fig.1.3

Summary of Contents for acer

Page 1: ...ES PARA LA INSTALACI N EL USO Y EL MANTENIMIENTO MOTORREDUCTOR ELECTROMEC NICO PARA PORT ES DE CORRER INSTRU ES PARA A INSTALA O USO E MANUTEN O ELEKTROMECHANISCHER SCHIEBETORANTRIEB ANLEITUNGEN UND H...

Page 2: ...nstalace viz obr zek Tab 1 ltal nos automatik hoz tartoz robbantott rajz l sd bra Tab 2 descrizione contenuto scatola attuatore ACER Fig 2 description of the contents of the ACER pack Fig 2 descriptio...

Page 3: ...D 20 15 10 Operating temperature C from 20 a 70 Protection class IP 54 Motor insulation class F D Assembly horizontal with dedicated anchorage plate Dimensions weight 170 plate x 342 x 288 h mm 10 kg...

Page 4: ...age plate R L c Refer to fig 2 2 for the respective heights for 16 or 18 tooth pinions d Lay the electric cable pipes 4 allowing them to protrude and plugging them to prevent them from filling with de...

Page 5: ...blocking the 4 M10 screws 7 and the relative washers with a fixed or tube wrench 10 Assemble the covers on the clamping feet 4 See fig 5 3 Fig 5 AC037 AC4 24P AC6 24 AC8 24 AC4 AC6 AC8 AC012 7 7 AC012...

Page 6: ...taut before the earth wire 2 2 Introducing the electric wires into the operator a To access the ECU remove the cover 2 of the reduction gear removing the two lateral clamping screws 1 b Open the pre p...

Page 7: ...cal knowledge of mechanics electronics and electrics and of sector laws and standards Amateur installation is strictly forbidden as it does not comply with current standards and laws and therefore doe...

Page 8: ...ne maintenance procedures as described in this manual This is the owner s duty Any checking maintenance or repair work must be conducted by a PROFESSIONAL FITTER Always switch of the electricity suppl...

Page 9: ...and garage doors and gates Safety in the usage of motorised doors testing methods EN 12453 2000 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 6...

Page 10: ...Page 15 Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it spot colour CMYK Instruction issue V 1...

Reviews: