LIFE home integration RG1RE Instructions And Warnings For Installation, Use And Maintenance Download Page 8

6.1   

Indicator LEDs

6.2  

List of electric cables

6.3

Setting up the electric system and connection to the mains supply

  

Connection cables

There is a row of 6 LEDs on the right hand side of the board, under the terminals.

These LEDs are lit when the corresponding signal is present.

For N.C. inputs 

STOP

,

PHOTO1

 and 

PHOTO

, the corresponding LEDs 

L7

,

 L11

and

L12

 are normally on.

For the N.O. inputs 

OPEN

,

CLOSE

 and 

STEP

, the corresponding LEDs 

L8

,

L9

and

L10

 will be switched off. These LEDs therefore indicate any malfunction of 

the connected devices.

•    Use the power supply cable provided with the operator only.

•    The power cable provided may not be extended or shortened

•    All wires must be unsheathed as little as possible (6mm at the most)

     as close as possible 

     to the connection terminals, in order to prevent accidental contact 

     with live parts should the cables disconnect from the terminals.

•    Do not pre-seal cables to be fastened to the terminals using screws.

•    If it is possible that wires subject to voltage higher than 50 Volt RMS 

     and very low voltage safety wires may come into contact with one 

     another, wires with voltage higher than 50 volt RMS must be insulated 

     with a sheath; voltage safety wire must have an insulating sheath at 

     least 1mm thick.

•    No external connection cables must be of the flat twin tinsel cord type.

ATTENTION: the cables used must be suited to the type of 

installation. It is the Fitter  ’s responsibility to choose 

appropriate material.

The cables needed may vary depending on the installation and type 

and quantity of devices installed.

The cables used in the installation must be IEC 60335 compliant.

Pos.

Type of cable

Connection

Electricity supply line

Internal button panel.

Sensitive strip (signal)

Power supply

Flashing light

Radio aerial

Tx Photo

Rx Photo

Selector

3x1,5 mm

2

cable

Cable supplied with Schuko socket

Screened RG58 50 Ω cable

4x1 mm

2

cable

2x1 mm

2

cable

2x1 mm

2

cable

3x1 mm

2

cable

3x1 mm

2

cable

2x1 mm

2

cable

This manual does not describe how the electrics system should be prepared for connection to the mains. It does, however, give the following warnings:

•   The electricity supply line must be installed and connected by an authorised electrician or professional fitter.

•   The electricity supply must be adequately protected against short circuits and static discharge. 

•   The power supply network must contain an omnipolar circuit breaker with a contact opening distance equal to or greater than 3.5 mm that assures

    the complete disconnection of the power supply. 

Fitters must make the connections of the 50 Hz 230 Vac electricity supply, and the various automation devices. 

Connections between the control unit, motor, encoder and transformer have already been performed by the Manufacturer.

•   Once the connections to the control unit have been made, the Fitter must use bands to join adjacent wires into groups of 2, 3 or 4 in order to prevent

    them coming away from the terminal board: bands must be attached as close as possible to the terminals, no more than 10mm away, taking care not

    to damage wire insulation. No cable may remain unpaired.  

•   The bands are only for unsheathed cables (sheathed cables are held in place by the sheath).

•   Pay careful attention not to pair wires with voltages higher than 50 Volt RMS with lower voltage wires. 

•   The wiring performed internally by the manufacturer is already equipped with clamping bands.

ATTENTION: the connections pre-wired by the manufacturer may not be altered under any circumstances.

L7

L8

L9

L10

L11

L12

Summary of Contents for RG1RE

Page 1: ...Rev 01 07 2013 LG RG1RE 24DL SUPRA CONTROL UNIT FOR BARRIER SUPRA 24V ...

Page 2: ...O Input Controls the movement of the barrier in the following ways Mode 1 Open Pause Close Pause Mode 2 Open Stop Close Stop Mode 3 Open only open PHOTO 1 N C Input for photocells or safety devices Determines the stop of the barrier in opening and closing The motion is recalled at the start when the photocell is disengaged or the safety device PHOTO N C Input for photocells or safety device In the...

Page 3: ... INDICATOR LIGHT 24 Vdc 3W max 1 7 8 9 10 11 13 15 16 17 18 19 2 20 12 14 3 4 5 6 22 23 L2 L1 RG58 50ohm AERIAL FOTO 1 STEP CLOSE OPEN STOP L11 L10 L9 L8 L7 COMMANDS COMMON N C N C N O N O N O FOTO N C L12 230 Vac 40W max FLASHING L1 L2 230 Vac OUTPUT 24 Vac 200 mA max OUTPUT 30 Vdc 200 mA max RELE 1 max 24V 1A N C N O RELE 2 max 24V 3A N C N O AGECH ...

Page 4: ...e barrier starts rolling if it and after start flashing The automation will perform in sequence a closure 1 an opening 2 a closure 3 an opening 4 Once programming is complete the two green LEDs will Flash and the red one will be fix Should the result obtained not be satisfactory repeat the whole process P H ASE 1 TOTAL RESET opens press again the start button to invert the movement The first limit...

Page 5: ...G NPNFOU 5P FYJU QSFTT UIF 5 CVUUPO UXJDF PS XBJU T NVTU CF UVSOFE Põ 1SFTT UIF CVUUPO 5 SFDFJWFS BOE WFSJGZ UIF JT nBTIJOH 1SFTT UIF CVUUPO PO UIF SFNPUF DPOUSPM POF PS NPSF SBEJP ZPV XBOU UP MFBSO BOE LFFQ JU QSFTTFE VOUJM UIF UVSOT Põ BOE PO BHBJO GPS B CSJFG NPNFOU 5P FYJU QSFTT UIF 5 LFZ UISFF UJNFT PS XBJU T NVTU CF UVSOFE Põ 1SFTT UIF CVUUPO UISFF UJNFT 5 PG UIF SFDFJWFS BOE DIFDL UIBU UIF ...

Page 6: ... led staying lit without flashing The button will de select the option led off Press 5 seconds then press in sequence to scroll through the options as shown by the five led s at the top The flashing of the led indicates the option selected The button is used to select the function indicated by the led staying lit The button will de select the option To exit continue to scroll through to option 5 N...

Page 7: ...he automation stops in a completely open position awaiting a command 2 During the opening phase if the control unit identifies an obstacle the automation performs a short reversal of motion and after it stops awaiting a command Wait 10 seconds or press again to quit Press for 5 seconds the red LED SX will light and then switch off Press and to set the various obstacle detection values MINIMUM MAXI...

Page 8: ...nnection Electricity supply line Internal button panel Sensitive strip signal Power supply Flashing light Radio aerial Tx Photo Rx Photo Selector 3x1 5 mm2 cable Cable supplied with Schuko socket Screened RG58 50 Ω cable 4x1 mm2 cable 2x1 mm2 cable 2x1 mm2 cable 3x1 mm2 cable 3x1 mm2 cable 2x1 mm2 cable This manual does not describe how the electrics system should be prepared for connection to the...

Page 9: ...r a short stretch 3 4 cm and then stopping until such time as new commands are given Obstacle N B In this situation release the automation and call for technical assistance The control intervenes by passing the system to the operation condition with dead man command and reduced speeds This class includes various incorrect and unsafe operation situations N B if the problems persist it is absolutely...

Page 10: ...ions adopted for eliminating or reducing risks manuals of the individual components list of the components used instructions for use and warnings concerning use by the owner system maintenance record declaration of the system s CE conformity b Fix a CE marking plate to the gate bearing at least the following information Name and address of the party responsible for installation and testing Type of...

Page 11: ...e with the following law 46 90 directive 98 37 EC 73 23 EEC 89 336 EEC and subsequent amendments He she must also make constant reference to harmonised standards EN 12453 and EN 12445 The indications given in this manual must always be observed when installing connecting adjusting testing and setting the control unit The Manufacturer declines all responsibility for damage or injury caused by non o...

Page 12: ...person with a similar qualification in order to avoid risks Do not perform technical or programming modifications on the control unit Operations of this type may cause malfunctions and or risk of accidents The manufacturer declines all responsibility for damage caused by products that have been modified In the event of intervention of automatic or fuse switches before restoring function conditions...

Page 13: ... 1 5RI 2 2AS 45 3 45 5 0 PNQPOFOUT BOE BVUPNBUJPO UZQF 41 3 1 354 ...

Page 14: ...otorised doors testing methods EN 12453 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 60204 1 1997 Machinery safety Electric equipment of the machine Part 1 general rules EN 60950 Information technology equipment Safety Part 1 General requisites ETSI EN 301489 3 2001 Electromagnetic compatibility for radio equipment and appliances EN 300220 3...

Page 15: ... ...

Page 16: ... Address Via Sandro Pertini 3 5 31014 COLLE UMBERTO TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it ...

Reviews: