1
CONNECTIONS
2
1
2
3 - 5
4 - 5
6
6 -7
6 - 8
6 - 9
6 - 10
6-11
6 - 12
13 - 15
14 - 15
16
17
18 - 19
19 – 20
22 - 23
L1 - L2
ANTENNA
: Input antenna ground.
ANTENNA
: Input antenna cable.
RELAY 1
: N.O. Contact second channel radio, 1A max 24V max.
Mode 1: Impulsive.
Mode 2: Step by Step. OPTION 2 third LEDs.
RELAY 1
: N.C. Contact second channel radio, 1A max 24V max.
Mode 1: Impulsive.
Mode 2: Step by Step. OPTION 2 third LEDs.
* Before commencing wiring and connection work, read the SAFETY INSTRUCTIONS AND WARNINGS and INSTALLATION INSTRUCTIONS
AND WARNINGS.
* All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply (and fr
om the buf
fer battery if present); if the disconnection device is not in view, display a sign reading
“ATTENTION: MAINTENANCE WORK IN PRO GRESS”.
COMMON
: Common of commands and of photocells Open Close Stop Step Photo1 Photo inputs.
STOP
: N.C. Imput controls the stop automation. For example can be connected safety devices such as
a button for emergency stop. The automatic closing is not allow when You release the command.
Leave the jumper if there is no device.
OPEN
: N.O. Input controls the opening of the barrier.
CLOSE
: N.O. Input controls the closing of the barrier.
STEP BY STEP
: N.O. Input Controls the movement of the barrier in the following ways:
Mode 1: Open-Pause-Close-Pause.
Mode 2: Open-Stop-Close-Stop.
Mode 3: Open (only open ).
PHOTO 1
: N.C. Input for photocells or safety devices. Determines the stop of the barrier in opening and
closing. The motion is recalled at the start when the photocell is disengaged or the safety device.
PHOTO
: N.C. Input for photocells or safety device. In the opening phase does not intervene, in closing
inverts the movement until fully open.
Leave the jumper if there is no device.
Leave the jumper if there is no device.
RELAY 2
: N.O. Contact for connecting accessories 3A 30V max.
Mode 1: Connect as flashing bright disk.
Mode 2: Connecting the traffic light. OPTION 2 four Led.
RELAY 2
: N.C. Contact for connecting accessories 3A 30V max.
Mode 1: Connect as flashing bright disk.
Mode 2: Connecting the traffic light. OPTION 2 four Led.
+ 30 Vdc
: DC output for powering accessories, 200 mA max.
- 30 Vdc
: DC output for powering accessories, 200 mA max.
INDICATOR LIGHT
: 24Vac 3W max, for the connection of an indicator light, blinking slowly on opening,
flashing closing in fast and steady light when the barrier is not closed.
24 Vac
: Power supply output for accessories, 200 mA max.
FLASHING
: 230Vac output 40W max, three ways of flashing:
Mode 1: Flashing slowly opening.
Mode 2: Flashing fast closing.
Mode 3: Three flashes and a pause to indicate unit ready for programming.
POWER SUPPLY
: Power Line 230Vac.