9
Lifecycle 9500HR / 9100 Series Recumbent Exercise Bikes
TROUBLESHOOTING GUIDE
Malfunction
Probable Cause
Corrective Action
Emitting loud noise.
Non-carpeted, hard floor.
Place bike on softer surface floor or carpeted
area to deaden sound.
Leaning excessively to either
side.
Do not lean.
Crank bearings not adjusted
properly or worn.
Inspect, adjust, and/or replace as necessary.
Alternator belt loose.
Inspect belt deflection. Adjust the Alternator
Belt to 1/4 inch (6mm) deflection.
Alternator Belt worn.
Replace Belt..
Malfunctioning Alternator.
While operating the unit, listen for excessive
noise from Alternator. Replace Alternator as
necessary.
Free-wheel Pulley not rotating
freely.
Inspect Pulley, and replace pulley as
necessary.
Seat wobbles.
Seat rollers out of adjustment
or excessively worn.
Inspect, adjust, or replace worn rollers as
necessary.
Alternator voltage test.
Malfunctioning Alternator.
1. Check the alternator voltage using a DC
voltmeter. Attach the positive (+) probe of the
voltmeter to the alternator RED lead, and the
negative (-) probe of the voltmeter to alternator
BLACK lead.
2. Pedal above 45 RPM.
3. Press the START key.
4. Voltmeter reading should be 9-11 VDC.
Sectio
n I
Summary of Contents for Lifecycle upright 9500HR
Page 17: ...11 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES Section I ...
Page 18: ...1 Lifecycle 9500 9100 Series Recumbent Exercise Bikes SECTION II DIAGNOSTICS Section II ...
Page 43: ...26 Lifecycle 9500 9100 Series Recumbent Exercise Bikes NOTES ...
Page 75: ...32 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 87: ...12 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 101: ...14 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES ...
Page 108: ...7 Lifecycle 9500HR 9100 Series Recumbent Exercise Bikes NOTES Section VI ...