![Life Fitness Integrity SL Service Manual Download Page 115](http://html1.mh-extra.com/html/life-fitness/integrity-sl/integrity-sl_service-manual_1908383115.webp)
Error 92
Error Message Displayed to user
•
E92
•
RPM MAX Error
Condition
This indicates that the console commanded an RPM value that was above the maximum allowed RPM value that the
MC supports. This should not happen in the field - notify Engineering.
Cause
• Wrong base type
• Corrupt software on console, MDB, or SIB
Remedy
Reload software if possible.
Page 113 of 153