background image

Chapter 7 – Limited warranty

UPStation GXT 3x1

Page 24

(06/02)

7.1

 

Limited Warranty

LIMITED WARRANTY

Liebert Corporation extends the following LIMITED WARRANTY to
the purchaser and to its customer (collectively referred to as the
"Purchaser"): the enclosed Uninterruptible Power System (UPS) and
components are free from defects in materials and workmanship
under normal use, service, and maintenance FOR A PERIOD OF
TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE from
Liebert or the Liebert dealer or retailer. THE FOREGOING
WARRANTY IS THE ONLY WARRANTY GIVEN AND NO OTHER
WARANTY IS PROVIDED, EXPRESS OR IMPLIED, INCLUDING
WITHOUT LIMITATION, MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. Certain aspects of disclaimers are not
applicable to consumer products acquired by individuals and used for
personal, family, or household purposes (as distinguished from
industrial or other purposes). Local laws may not allow limitations on
how long an implied warranty lasts, so the above limitation may not
apply to you. This warranty gives you specific legal rights, and you
may have other rights which vary according to local law.
Certain repairs or services are the responsibility of the Purchaser and
the Purchaser is expected to pay for them. This warranty does not
extend either to products with removed or altered serial numbers or to
any losses or damages due to act of God or source external to the
product, misuse, accident, abuse, neglect, negligence, unauthorised
modification, alteration, or repair, use beyond rated capacity, or
improper installation, maintenance, application or use, including,
without limitation, use in a manner contrary to the accompanying
instructions or applicable codes.  WARNING: Warranty is void if the
battery is allowed to discharge below the minimum battery cut-off
point. The battery must be recharged every four (4) to six (6) months
when not in use.
If the UPS fails to conform with the above warranty within the two
year warranty period, Liebert will repair or replace the UPS, at
Liebert's option. Repairs or replacements are warranted for the
remainder of the original warranty period. Purchaser, to make a
warranty claim, should call to obtain a Returned Goods Authorisation
number and shipping instructions. Return transportation costs to
Liebert are the responsibility of the Purchaser.

"LIFE SUPPORT" APPLICATIONS

Due to the diversity of applications and considerations to be applied
in each case, Liebert does not recommend or knowingly sells its
products for such use.

The responsibility for risk assessment and management in
applications where the malfunction or failure of the UPS could be
reasonably expected to give rise to a risk of human life shall be the
sole responsibility of the purchaser. Liebert accepts no liability for
consequential harm in such applications.

Summary of Contents for UPSTATION GXT3X1-10000

Page 1: ...Manual Reference number 6390010Q En 06 02 U UP PS ST TA AT TI IO ON N G GX XT T T TM M 3 3x x1 1 6 6 8 8 1 10 0 k kV VA A U Us se er r M Ma an nu ua al l...

Page 2: ...D D DR R R...

Page 3: ...with the procedures contained in this manual you should seek immediate assistance from the Liebert Sales Office from whom the equipment was purchased Alternatively contact the Liebert s Customer Servi...

Page 4: ...UPStation GXT 3x1 USER MANUAL Page iv 06 02...

Page 5: ...interference which the user must correct at his own expense 5 Operate the UPS in an indoor environment only in an ambient temperature range of 0 C to 40 C 32 F to 104 F Install it in a clean environm...

Page 6: ...S Indicates AC Input Indicates AC Output Indicates Caution Note the accompanying instruction Indicates the position of a fuse Requests the user to consult the manual for additional information Indicat...

Page 7: ...ion When fitted 7 2 5 Commissioning the UPS 8 2 5 1 Output Voltage Selector Switches 8 3 CONTROLS AND INDICATORS 11 4 OPERATING MODES 13 4 1 Introduction 13 4 1 1 Normal mode operation UPS mode 13 4 1...

Page 8: ...UPStation GXT 3x1 USER MANUAL Page viii 06 02 7 SPECIFICATIONS 23 7 1 Limited Warranty 24...

Page 9: ...3x1 230X models have an additional output isolation transformer For ease of use the UPStation GXT contains a light emitting diode LED display to indicate either load percentage or battery capacity dep...

Page 10: ...at charge the battery system The battery system charges whenever the UPStation GXT is connected to mains power 1 2 5 Battery The UPStation GXT employs valve regulated non spillable lead acid batteries...

Page 11: ...floor without the stabilisers fitted that it does not tip over Follow the instructions in Chapter 2 Stabilisers Levelling feet IMPORTANT Check the UPS rating plate that the UPS is suitable for operat...

Page 12: ...mend that the input mains supply be protected with an MCB capable of withstanding this initial inrush An MCB specified as being TYPE 4 British standard or CURVE D IEC standard is suitable for this pur...

Page 13: ...1 Safety earth cable Properly grounded earthed equipment provide multiple benefits High quality ground earth connections are required for the equipment ground conductors protective earth and groundin...

Page 14: ...with flexible cables this is optional Note Access to the levelling feet is obstructed by the stabiliser brackets on the GXT 3x1 6000 8000 10000 models Adjust the levelling feet as necessary using a 12...

Page 15: ...lose as possible to the end of the cable that connects to the DB9 connector of the UPS Close the ferrite bead so that the ferrite bead s case snaps closed with the cable routed inside the ferrite bead...

Page 16: ...perating instructions to check functionality of the UPS 3 Set the UPS to NORMAL MODE OPERATION UPS mode Check on the output terminals of the UPS for the correct output voltage for the voltage rating o...

Page 17: ...02 Page 9 Figure 2 3 GXT 3x1 6 8 10 kVA Rear panel controls Intellislot Communications Port TM DB 9 Communications Port Terminal Blocks Output Voltage Selector Switches Output Breaker Breakers Input I...

Page 18: ...Chapter 2 Installation UPStation GXT 3x1 Page 10 06 02 This page is left blank intentionally...

Page 19: ...indicators display approximate battery capacity The UPStation GXT 3x1 is equipped with automatic and remote battery test features The automatic test occurs every 14 days if a manual battery test has n...

Page 20: ...act your dealer or Global Services for a battery replacement OUTPUT OFF BYPASS Button This button controls output power to connected load s and has dual functions OUTPUT OFF and BYPASS CAUTION Pressin...

Page 21: ...lies power through the Rectifier PFC to the inverter to generate power for the connected load During battery mode the AC Input LED will extinguish and the Battery LED will illuminate to warn that a ma...

Page 22: ...the UPS will be operated with mains available The UPS can operate in three possible modes with mains available NORMAL MODE OPERATION UPS ON LED will be on and the inverter will provide power to the lo...

Page 23: ...ave been turned off to prevent the batteries from being completely drained It may also be desirable to power up the loads for a short time without mains power to support a critical operation With main...

Page 24: ...or other local safety codes it is necessary to interrupt at the same time with the same pushbutton all mains input supplies to the UPS The pushbutton that provides the UPS remote shutdown must be of t...

Page 25: ...lity to communicate intelligently with stand alone computers network workstations network servers or UNIX hosts via the DB 9 socket located at the rear of the UPS By purchasing the optional Liebert Si...

Page 26: ...S TxD typical RS 232 levels 3 UPS RxD typical RS 232 levels 4 Remote Shutdown 5 12V battery operation 5 Common 6 Remote Shutdown short to pin 5 any mode 7 Low Battery open emitter 8 Mains Fail open em...

Page 27: ...he operator as described below All On bypass due to output overload beep every half second A On bypass due to over temperature condition beep every 4 seconds B On bypass due to DC bus over voltage bee...

Page 28: ...use is blown indicating internal fault Do not attempt to open or service the UPS Contact your dealer or technical support UPS fails to start when on button is pressed Breaker not closed or has tripped...

Page 29: ...are illuminated UPS inverter fault UPS requires service Contact your dealer or technical support Fault indicators and diagnostic LED A C are illuminated UPS failed the battery test Replace batteries C...

Page 30: ...Chapter 6 Troubleshooting UPStation GXT 3x1 Page 22 06 02 This page is left blank intentionally...

Page 31: ...8 cycles min 201 for 96 msec min with transfer to bypass BYPASS PARAMETERS Default Acceptable Input Voltage for transfer to BYPASS Nominal 15 User selectable Default Acceptable Input Frequency for tr...

Page 32: ...or altered serial numbers or to any losses or damages due to act of God or source external to the product misuse accident abuse neglect negligence unauthorised modification alteration or repair use b...

Reviews: