Liberty Pumps LSG200 Series Installation Manual Download Page 10

10 | EN

Copyright © Liberty Pumps, Inc. 2021 All rights reserved.

5647000M

Pump does not start.

Loose wiring connections.

Check and tighten all connections.

Thermal overload tripped.

Wait for pump to cool to operating temperature.

Water inside motor.

Check/replace oil, oil plug, and sealing washer as needed.

Damaged lower lip seal or mechanical seal. Replace seal. 

Replace oil as needed.

Damaged O-ring between oil chamber and motor plate. 

Return to authorized repair facility for O-ring and oil 

replacement.

Damaged cord. Replace as needed.

Pump does not start 

and overload heaters 

trip.

Unintentional ground.

Turn off power and check motor leads for possible 

ground.

3-phase motor winding failure.

Check resistance of motor windings. All three phases 

should have the same reading.

Obstructed impeller or volute.

Remove obstruction.

Pump operates with 

control panel selector 

switch in Hand position 

but does not operate in 

Auto position.

Control circuits malfunctioning.

Check float level control or the alternator relay for issues.

Check control panel.

Pump runs but does not 

turn off.

Pump is airlocked.

Turn pump off and let set for several minutes, then 

restart.

Control panel selector switch in Hand position.

Set selector switch to Auto position.

Float switch unable to move to the pump OFF 

position due to interference with the side of 

basin or other obstruction.

Position the pump or float switch so that it has adequate 

clearance for free movement.

Control panel failure.

Check control panel.

Defective float switch.

Replace float switch.

Missing or faulty curb stop/swing check valve 

allowing system pressure to feed back through 

discharge piping.

Verify presence of a curb stop check valve or replace curb 

stop/swing check valve assembly.

Pump does not deliver 

proper capacity.

Discharge valve(s) partially closed or clogged.

Check the discharge line for foreign material, including 

ice if the discharge line passes through or into cold areas.

Check valve partially clogged.

Raise liquid level up and down to clear; remove check 

valve to remove obstruction.

Incorrect motor rotation.

1-phase internal capacitor models: contact factory.

1-phase exterior capacitor models: verify capacitor wiring 

in Figure 1, else consult factory.

3-phase: Correct 3-phase pump rotation direction. Refer 

to section 

3-Phase Pump Rotation Verification

.

Total head is beyond pump's capability.

Route discharge piping to a lower level. If not possible, a 

larger pump may be required. Consult Liberty Pumps.

Low liquid level.

Check liquid level.

Obstruction in pump or piping.

Remove obstruction.

Table 3. Troubleshooting Matrix (continued)

Problem

Possible Cause

Corrective Action

Summary of Contents for LSG200 Series

Page 1: ...ps at 1 800 543 2550 Retain dated sales receipt for warranty Serial Mfg Date Install Date Installation Manual 5647000M Copyright Liberty Pumps Inc 2021 All rights reserved For pressure sewer applicati...

Page 2: ...by its power cord This will damage the power cord and could expose the electrically live wires inside the power cord The electrical power supply shall be located within the length limitations of the p...

Page 3: ...iates poisonous gas buildup and reduces the risk of explosion and fire from these flammable gases Wear adequate Personal Protective Equipment when working on pumps or piping that have been exposed to...

Page 4: ...e Before Use Protect the power and control cords from the environment Unprotected power and control switch cords can allow water to wick through ends into pump or switch housings causing surroundings...

Page 5: ...stat integrally mounted to the motor and wired to shut down the pump if overheating occurs The thermostat resets automatically after the pump has cooled Power and Control Cords Do not remove cord and...

Page 6: ...ineering drawings will generally specify the levels for Pump ON Pump OFF and HIGH LEVEL ALARM If they are not specified the guidelines in Table 2 should be used to determine float switch locations The...

Page 7: ...pplied with a 6 20P 20A cord plug end If a 1 phase pump will be wired directly into a junction box it is necessary to remove the plug Qualified personnel shall complete the wiring in accordance with t...

Page 8: ...are used refer to the separate instructions supplied with the unit for proper installation and operation making sure all gaskets and components are present Liberty Pumps GR20 Guide Rail System featur...

Page 9: ...k valve operation 4 For multiple pumps check for balanced operating times Uneven times indicate a defective unit float switch or control 5 Inspect the control panel for any presence of moisture in enc...

Page 10: ...to Auto position Float switch unable to move to the pump OFF position due to interference with the side of basin or other obstruction Position the pump or float switch so that it has adequate clearan...

Page 11: ...obstruction Pump is airlocked Turn pump off and let set for several minutes then restart Add baffle to reduce trapped air bubbles Capacitor failure in control panel Check capacitors and replace if nee...

Page 12: ...r transportation There is no other express warranty All implied warranties including those of merchantability and fitness for a particular purpose are limited to three years from the date of purchase...

Reviews: