AS-2H-WP Installation Guide
18
Description
Command
Response
Factory Reset
RST<CR><LF>
No response for 7 seconds until device
power cycles
Factory Reset
The factory reset command will reset every setting to the factory defaults. EDID, HDCP, scaling, and Display Control
settings will all be reset to the original settings. Use extreme caution when the device is used in a live environment.
HDCP Compliance
Device Information
Device Baud Rate
Description
Command
Response
HDCP Compliance ON
HDCP ON<CR><LF>
HDCP ON!<CR><LF>
HDCP Compliance OFF
HDCP OFF<CR><LF>
HDCP OFF!<CR><LF>
Get HDCP Compliance status
GET HDCP<CR><LF>
HDCP ON! <CR><LF>
OR
HDCP OFF!<CR><LF>
Description
Command
Response
Get device model
MODEL?<CR><LF>
AS-2H!<CR><LF>
Get firmware revision
REV?<CR><LF>
V1.0.5<CR><LF>
The default baud rate for the AS-2H is 9600. This can be changed to accommodate various installation needs: 2400,
4800, 9600, 19200, 38400, 57600, 115200.
If the baud rate has been changed, but the rate is unknown, a hardware reset (see
) must be performed
on the device.
Description
Command
Response
Change device baud rate (xxxx = new
baud rate)
SET xxxx<CR><LF>
baud rate is set to xxxx<CR><LF>
Get device baud rate
GET BAUD<CR><LF>
baud rate is set to xxxx<CR><LF>