background image

AS-2H-WP Installation Guide

20

Display Control Settings

Description

Command

Response

Turn Display Control ON 

DFG1

DFG1!<CR><LF> 

Display Control On<CR><LF>

Turn Display Control OFF 

DFG0

DFG0!<CR><LF> 

Display Control Off<CR><LF>

Store the ON command for Display 

Control (xx = up to 25 characters)

DONxx 

Example:

 

DONpwron

DON!<CR><LF> 

pwron<CR> 

<CR><LF>

Store the OFF command for Display 

Control (xx = up to 25 characters)

DOFxx  

Example:

  

DOFpwroff

DOF!<CR><LF> 

pwroff<CR>

 

<CR><LF>

Store the input select  command 

for  Display  Control  (xx  =  up  to  25 

characters)

DISxx  

Example:

  

DIShdmi1

DIS!<CR><LF> 

hdmi1<CR> 

<CR><LF>

Store  the  time  between  power  on 

and input select  commands (xxx = 

time in seconds – 3 characters)

DDCxxx 

Example for 5 sec�:

  

DDC005

DDC!<CR><LF> 

Input Delay  Time: 10 S<CR><LF>

Store the “No signal” timeout value 

(xxx = time in minutes – 3 characters) 

DNSxxx 

Example for 30 min�:

  

DNS030

DNS!<CR><LF> 

No Signal Time: 30 M<CR><LF>

Disable the “No signal” timeout

DNS000

DNS!<CR><LF> 

No Signal Time: 0 M<CR><LF>

Store the “No activity” timeout value 

(xxx = time in hours – 3 characters)

DNAxxx 

Example for 4 hours:

  

DNA004

DNA!<CR><LF> 

No Activity Time: 4 H<CR><LF>

Disable the “No activity” timeout

DNA000

DNA!<CR><LF> 

No Activity Time: 0 H<CR><LF>

Display baud rate 115200

DBR1

DBR!<CR><LF> 

Baudrate : 115200<CR><LF>

Display baud rate 57600

DBR2

DBR!<CR><LF> 

Baudrate : 57600<CR><LF>

Display baud rate 19200

DBR3

DBR!<CR><LF> 

Baudrate : 19200<CR><LF>

Display baud rate 9600

DBR4

DBR!<CR><LF> 

Baudrate : 9600<CR><LF>

Display baud rate 38400

DBR5

DBR!<CR><LF> 

Baudrate : 38400<CR><LF>

Display baud rate 4800

DBR6

DBR!<CR><LF> 

Baudrate : 4800<CR><LF>

Display baud rate 2400

DBR7

DBR!<CR><LF> 

Baudrate : 2400<CR><LF>

Summary of Contents for Intelix AS-2H-WP

Page 1: ... 160111 Toll Free 800 530 8998 Fax 719 260 0075 supportlibav libav com HDMIAuto SwitchingWallplate AS 2H WP PoH In HDBT Out 12V IN 12V TX RX GND Auto HD 2 HD 1 OUT RS232 HDCP LINK Firmware Reset HDMI 1 HDMI 2 AS 2H WP Installation and Operation Guide ...

Page 2: ......

Page 3: ... apparatus has been damaged in any way such as the power supply cord or plug is damaged liquid has been spilt or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 CAUTION Servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing oth...

Page 4: ...er to the presence of non insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock 28 WARNING To reduce the risk of electric shock do not remove cover or back as there are no user serviceable parts inside Refer servicing to qualified personnel 29 The exclamation point within an equilateral triangle is intended to alert th...

Page 5: ... 11 Auto Switching with Manual Override 11 Device Power 11 12V DC Output Power 12 RS232 Connections 12 Third Party Device Connections 12 General Operation 13 Automatic Switching 13 Contact Closure Switching 13 RS232 Switching 13 LED Indicators 13 Inputs 13 Status 13 Reset Button 14 Firmware Port 14 EDID Management 14 HDCP Management 14 Low Power Mode 15 No Signal 15 No Activity 15 Changing Low Pow...

Page 6: ... 18 Factory Reset 18 EDID Configuration 19 Display Control Settings 20 Display Control Queries 21 Display Control Hex Commands 21 Troubleshooting 22 Device does not power on 22 Cannot view 4K UHD content 22 Cannot hear surround sound audio 22 No video from HDBaseT output 22 Device does not respond to RS232 commands 22 Technical Specifications 23 ...

Page 7: ...urs by default When using the local power input 12V DC is available for other devices on the power output connections on the rear of the device The AS 2H WP will detect which input has an active video input and switch to that input if both inputs are active the last in will be selected There are additional contact closure inputs provided on the rear of the unit to allow third party control RS232 c...

Page 8: ...de 8 Front and Rear Panels Front Panel 1 2 3 4 HDCP LINK Firmware Reset HDMI 1 HDMI 2 1 HDMI input 1 and input status LED 2 Status LEDs and Reset button 3 HDMI input 2 and input status LED 4 Micro USB port for firmware updating ...

Page 9: ...e 9 Rear Panel A Contact closures B 12V DC power input C HDBaseT output with PoH input support D RS232 and 12V DC output A B C D HDMIAuto SwitchingWallplate AS 2H WP PoH In HDBT Out 12V IN 12V TX RX GND Auto HD 2 HD 1 OUT RS232 ...

Page 10: ... of the installation connect an HDMI cable between the display and the HDMI output port on the AS 2H WP 6 Power on attached audio video devices 7 Apply power to the HDBaseT receiver 8 If the HDBaseT receiver cannot provide power to the AS 2H WP connect the power supply going to the AS 2H WP to an AC outlet 9 Connect HDMI sources HDBaseT Cabling Requirements For all HDBaseT cabling the EIA TIA 568B...

Page 11: ...ace if you wish the unit to switch automatically when a video signal is present The AS 2H WP supports two types of power input PoH Power over HDBaseT and rear panel input When using PoH a compatible HDBaseT receiver can power the AS 2H WP by inserting power onto the twisted pair cable When using a compatible HDBaseT receiver there is no need to use the rear panel power input If using a different r...

Page 12: ...pabilities of the AS 2H WP connect the TX ground and RX control signal wires to the removable 4 pole terminal block Consult the manual of the control device s to determine which pins the TX and RX signals are carried on Be sure to always connect TX to RX and RX to TX With the built in Display Control functionality the AS 2H WP can automatically turn on and turn off the display when a source is con...

Page 13: ...sh button control of the input selection on the AS 2H WP When using Auto switching with manual override the unit will function as described in the Auto section above but pressing one of the override buttons will cause the unit to switch to the selected input If there is no video signal connected to the selected input you will experience a black video screen When using Manual switching mode the uni...

Page 14: ... perfectly for the display In addition to the default EDID pass through mode there are many built in EDID settings to define the source video output resolution The built in EDID tables range from XGA 1024x768 up to UHD 30 3840x2160 at 30 Hz Changing the EDID is performed via RS232 and the commands can be found on page 19 HDCP Management The AS 2H offers advanced HDCP management to allow greater co...

Page 15: ... disable the timeout the next two commands to send to the unit would be Disable the No Signal Timeout DNS000 and Disable the No Activity Timeout DNA000 These commands are found on page 20 Display Control via RS232 Display Control Software Display Control Functionality The Display Control functionality may be set up through RS232 commands direct to the AS 2H WP or via HDBaseT through a compatible r...

Page 16: ...e device RS232 settings have been changed 1 Short the HD 1 and HD 2 contact closures to Ground for 10 seconds 2 Without removing the shorted HD 1 and HD 2 contact closures short the Auto contact closure to Ground for 3 seconds The input LEDs will flash to indicate the reset was performed correctly 10 seconds 3 seconds GND Auto HD 2 HD 1 GND Auto HD 2 HD 1 ...

Page 17: ... SET HDMI1 CR LF SET HDMI1 CR LF Select HDMI input 2 SET HDMI2 CR LF SET HDMI2 CR LF Get selected input GET IN CR LF GET IN CR LF AND HDMI1 1 CR LF OR This response indicates HDMI input 1 is selected HDMI2 1 CR LF This response indicates HDMI input 2 is selected Get HDMI 1 video status GET HDMI1 CR LF HDMI1 1 CR LF OR This response indicates video present on HDMI input 1 HDMI1 0 CR LF This respons...

Page 18: ...P ON CR LF HDCP Compliance OFF HDCP OFF CR LF HDCP OFF CR LF Get HDCP Compliance status GET HDCP CR LF HDCP ON CR LF OR HDCP OFF CR LF Description Command Response Get device model MODEL CR LF AS 2H CR LF Get firmware revision REV CR LF V1 0 5 CR LF The default baud rate for the AS 2H is 9600 This can be changed to accommodate various installation needs 2400 4800 9600 19200 38400 57600 115200 If t...

Page 19: ...ID WUXGA CR LF EDID WUXGA CR LF 1360x768 EDID WXGA2 CR LF EDID WXGA2 CR LF 1280x800 EDID WXGA CR LF EDID WXGA CR LF 1600x1200 EDID UXGA CR LF EDID UXGA CR LF 1400x1050 EDID SXGAP CR LF EDID SXGAP CR LF 1024x768 EDID XGA CR LF EDID XGA CR LF EDID from display EDID PT CR LF EDID PT CR LF Get EDID setting GET EDID CR LF EDID PT CR LF The EDID settings listed below will be passed to both HDMI inputs ...

Page 20: ... DDC005 DDC CR LF Input Delay Time 10 S CR LF Store the No signal timeout value xxx time in minutes 3 characters DNSxxx Example for 30 min DNS030 DNS CR LF No Signal Time 30 M CR LF Disable the No signal timeout DNS000 DNS CR LF No Signal Time 0 M CR LF Store the No activity timeout value xxx time in hours 3 characters DNAxxx Example for 4 hours DNA004 DNA CR LF No Activity Time 4 H CR LF Disable ...

Page 21: ...iption Command Store the ON command for Display Control xx up to 25 bytes 44 4F 4E xx Example 44 4F 4E 54 68 69 73 20 69 73 20 4F 4E Store the OFF command for Display Control xx up to 25 bytes 44 4F 46 xx Example 44 4F 46 54 68 69 73 20 69 73 20 4F 46 Store the input select command for Display Control xx up to 20 bytes 44 49 53 xx Example 44 49 53 54 68 69 73 20 69 73 20 49 4E The query responses ...

Page 22: ... use the included power supply power input on the device Set EDID to pass through Verify output can broadcast surround sound audio Verfiy source content contains surround sound audio Double check RS232 wiring see page 12 Verify baud rate matches those of the device Perform a hardware reset to restore the device to the factory settings see page 16 Set EDID to UHD or pass through Verify display is 4...

Page 23: ...60 m Cable Requirements Solid core shielded Category 5e Category 6 or greater with TIA EIA 568B crimp pattern Bandwidth 10 2 Gbps HDBaseT Chipset VS010TX Chassis and Environmental Construction Alumininum Housing Dimensions H x W x D 104 mm x 89 mm x 51 mm 4 09 in x 3 50 in x 2 01 in Shipping Weight 0 68 kg 11 5 lbs Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 20 to 90 Non condens...

Page 24: ...Intelix is a brand of 11675 Ridgeline Drive Colorado Springs Colorado 80921 USA Phone 719 260 0061 Fax 719 260 0075 Toll Free 800 530 8998 ...

Reviews: