AS-2H-WP Installation Guide
14
Reset Button
The reset button located under the Status Indicators will reboot the AS-2H-WP. This may need to be used if in EDID
pass-through mode, and the AS-2H-WP was powered on before the display during installation, which may prevent
the EDID from being read correctly.
Firmware Port
EDID Management
A separate document will provide usage instructions once a new firmware update is available.
An essential part of operation is the EDID table, which is transmitted to the source from the AS-2H input.
The AS-2H features a pass through EDID mode for both HDMI inputs. The preferred native timing of the display
will be transmitted to the source. If the resolution of the TV connected to the output is 1080p, then the switcher
will request the source to output 1080p. The benefit of this method is that the video output by the source will be
formatted perfectly for the display.
In addition to the default EDID pass-through mode, there are many built-in EDID settings to define the source
video output resolution. The built-in EDID tables range from XGA (1024x768) up to UHD/30 (3840x2160 at 30 Hz).
Changing the EDID is performed via RS232, and the commands can be found on
HDCP Management
The AS-2H offers advanced HDCP management to allow greater compatibility with other devices. The output
will always be encrypted or unencrypted, following the status of the source content. If the content is encrypted,
the output of the HDBaseT receiver will be encrypted; if the content is unencrypted, the output of the HDBaseT
receiver will be unencrypted.
The AS-2H ships with the HDMI inputs set to “HDCP compliant”. This will work for most applications; however, the
AS-2H allows you to set the input to “Not HDCP compliant”. This is important for systems using not-compliant sinks
(such as a video conferencing or recording system). To set the unit to “Not HDCP compliant”, simply connect via
RS232 and send the RS232 command as described on page 18.