Maintenance Manual of Elevating Work Platform
16
(can smell “hot” but not “burnt”) or rubbing
between fingers (should feel viscous and free
of any rough feel due to particles) If the
hydraulic oil passes all of the above
inspections,
continue
the
scheduled
maintenance intervals. If the hydraulic oil
fails any of the above inspections, the
hydraulic oil must be tested by an oil
distributor or replaced.
Note: If the hydraulic oil has not been replaced for
two years, the oil must be tested every quarter by
an oil distributor until the oil fails the test and is
replaced. After the oil has been replaced,
continue the scheduled monthly maintenance
inspection.
Note: When replacing the hydraulic oil, it is
recommended that all hydraulic filters be replaced
at the same time.
B-12
Inspection of ventilation system of hydraulic
oil tank cover
This check shall be made once per 25h or per
month, whichever is shorter.
1) The well-ventilated hydraulic oil tank cover is
essential to the good mechanical property
and service life. The dirty or blocked exhaust
cover
may
degrade
the
machine
performance. The frequent inspection is the
must for the poor working environment.
①
Remove the exhaust cover from the
hydraulic oil tank cover.
②
Check ventilation
Result: The air can pass through the exhaust
cover.
Result: If the air is unable to pass through the
exhaust cover, clean or replace the exhaust
cover. Continue Step 3.
△
!
Notice: when checking the
ventilation of the oil tank cover, the air
shall freely pass through such cover.
2) Carefully wash the oil tank exhaust cover
with mild solvent and dry it with the
low-pressure compressed air. Repeat step 2.
3) Install the exhaust cover of hydraulic oil tank
B-13
Inspection of chassis tray locking component
This check shall be made once per 25h or per
month, whichever is shorter.
1) The good conditions of chassis tray locking
component are essential to the equipment
performance and service life. The tray may
be unexpectedly opened and the safety
hazard can be caused by the damaged
chassis tray locking component. Check the
abrasion and damage of each chassis tray
locking component.
B-14
Inspection of lower limit and hollow protector
switch
This check shall be made once per 25h or per
month, whichever is shorter
Summary of Contents for AS0607E
Page 6: ...Maintenance Manual of Elevating Work Platform 1 Chapter 1 Maintenance...
Page 7: ...Maintenance Manual of Elevating Work Platform 2...
Page 33: ...Maintenance Manual of Elevating Work Platform 28...
Page 34: ...Maintenance Manual of Elevating Work Platform 29 Chapter 2 Appendix...
Page 35: ...Maintenance Manual of Elevating Work Platform 30...
Page 36: ...Maintenance Manual of Elevating Work Platform 31 2 1Battery Maintenance Schedule...
Page 41: ...Maintenance Manual of Elevating Work Platform 36 SS0407E SS0507E HYDRAULIC SCHEMATIC...
Page 42: ...Maintenance Manual of Elevating Work Platform 37 AS0607E HYDRAULIC SCHEMATIC...
Page 43: ...Maintenance Manual of Elevating Work Platform 38 AS0812E HYDRAULIC SCHEMATIC...
Page 44: ...Maintenance Manual of Elevating Work Platform 39 AS1012E AS1212E HYDRAULIC SCHEMATIC...
Page 45: ...Maintenance Manual of Elevating Work Platform 40 AS1413E HYDRAULIC SCHEMATIC...
Page 46: ...Maintenance Manual of Elevating Work Platform 41 SS07E ELECTRIC SCHEMATIC...
Page 47: ...Maintenance Manual of Elevating Work Platform 42 AS07E AS08E AS12E ELECTRIC SCHEMATIC...
Page 48: ...Maintenance Manual of Elevating Work Platform 43 AS1413E ELECTRIC SCHEMATIC...