15
EN
NOTE
• Installation in a confine
d
space without
proper ventilation will lea
d
to higher power
consumption.
• Auxiliar
y
drain pan
MUST b
e installe
d
in
complian
c
e with local codes.
Drain pan kits are available from the store
where the water heater purchased, or any
water heater distributor.
Drain pan shoul
d
not obstruct cold water inlet
or drain valve.
- Select space where has enough space for
periodi
c
servicing. The air filter, covers, and
front panels can
b
e remove
d
to permit
inspection an
d
servicing.
-
T
ake the weight of the water heater into
account an
d
select a place where the floor is
strong enough to support the weight of full
water heater.
- The water heater an
d
water lines shoul
d
be
protecte
d
from freezing an
d
high corrosive
elements. Do not install water heater in
outdoor or unprotecte
d
areas.
- Install the water heater close to the area of
the greatest heater water deman
d
an
d
the
center of plumbing system. Long uninsulated
hot water lines can waste energ
y
.
- Insufficient air exchange will result in
increase
d
energ
y
consumption level.
- The installation site must be over 1 °C.
Minimum Clearances
Minimum room size:
20 m
3
0.15 m
0.15 m
0.45 m
0.15 m
0.45 m
0.5 m
Select the best Location
NOTE
• For future service, a minimum 1 m clearance
between any object and the left, right and
back side is recommended.
Ensure the water heater is horizontal using a
spirit level.
Keep level parallel in installing the product.
Otherwise, it may cause vibration or water
leakage. It may cause injury or an accident.