- 104 -
LGE Internal Use Only
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
4. TROUBLE SHOOTING
1.TROUBLE SHOOTING
PAM IN/OUT Signal :
When PAM is under the operation of high power mode (
PA_R0 (C113, C220)
:
Low),
PAM OUT power must be over 21 dBm
PAM IN power must be under 10 dBm
TP2
TP1
TP3