26
Air Conditioner
Wiring Connection
• Open the control box cover and connect the Remote controller cord and Indoor power wires.
[Air inlet side view]
Control box cover
Indoor
power cord
Remote
controller
cord
Control box cover screw
The power cord
connected to the outdoor unit should be
complied with the following specifications (Rubber
insulation, type H05RN-F approved by HAR or SAA).
If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer of its service agent.
The connecting cable
connected to the indoor and outdoor
unit should be complied with the following specifications
(Rubber insulation, type H05RN-F approved by HAR or SAA).
CAUTION
20mm
GN/YL
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 0.75mm
2
(24/30/36k Btu/hr)
Capacity
24/30/36k Btu/h
1 Phase
2.5mm
2
NORMAL CROSS-SECTIONAL AREA
Power Input
1(L) 2(N)
3
Terminals on the Indoor Unit
Terminals on the outdoor unit
1(L) 2(N) 3
2(N)
1(L)
W
ARNING:
Make sure that the screws of the terminal are free from looseness.
Wiring Connection
Summary of Contents for UU24WD
Page 44: ...P No MFL40910603 ...