14
Air Conditioner
The Indoor Unit Installation
3. Convertible type
Open side cover
1. Remove two screws from side-cover as
shown in fig.
2. Unlock side-cover from side panel by slightly
pulling the edge of side cover.
3. Tap the side-cover with your palm on the
backside.(Inlet grill side.)
4. Hold the side-cover with other hand while
tapping to prevent it to fall down.
5. The Drain hole is on the left side of the unit
and side cover opening is common for drain
pipe,connecting pipe and wiring diagram.
6. Remove the rubber stopple in the desired
drain direction.
7. Knock out the pipe hole from the left side-
cover with the help or nipper/plier.
8. Knock hole on right side-cover only if right
side is selected for water drain.
2
1
Edge part
Summary of Contents for UU24WD