43
ENGLISH
PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
Checking point
Display
None
LqC 1
1 time
Check the version and code of machine
GAS TYPE: P2:Og
Version and code of machine(All LED on)
Display P2:Og, tu:XX, td:XX and tS:XX
alternately. XX is the version number
2 time
PDA CHECK
Ir--
3 time
Drum Motor runs
Measured moisture value (70~239)
4 time
Blower Motor runs
Blower Motor RPM (~3000)
5 time
GAS TYPE: GAS valve runs
Drum Motor + Blower Moror + Valve
Display the blower motor RPM and the temperature
inside the drum in Celsius alternately
1.Blower Motor RPM (~3000)
2.Current temperature (5~70)
6 time
LED & KEY CHECK
Press High Temp. button
Press Med Temp. button
Press Low Temp. button
Press No Heat button
Version and code of machine
7 time
Test ends.
LqC1
During check, if the
Door or LintFilter is
open
Door switch
(Drum Motor & Blower Motor &
Heater Off, Buzzer seven times)
LintFilter switch
(Drum Motor & Blower Motor &
Heater Off, Buzzer seven times)
dE (the door or lint filter is open. Please close the door
and lint filter completely)
During check, if the
Door and LintFilter
is closed
Test goes back at step 3
(Drum Motor on & Blower Motor off &
Heater off )
Measured moisture value (70~239)
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
NOTE
MFL67863709_en_170328.indd 43
2017-03-28 �� 9:54:38