DIAGNOSTIC TEST
10
Test 6 Thermister check
Trouble Symptom : Poor drying performance(over-drying or no drying). Abnormal
thermistor operation.
Measurement condition : Power cord is unplugged.
Dryer
Temperature
• Check harness & connection
Dryer
Temperature
Resistance
TH-Heater
250~180k
Ω
180~113k
Ω
TH-Drum
19~111k
Ω
11~8k
Ω
8~5k
Ω
TH-Drum
19~111k
Ω
11~8k
Ω
8~5k
Ω
Resistance
Remark
TH1
113~75k
Ω
75~50k
Ω
50k
Ω
TH2
5~4k
Ω
4~2.5k
Ω
2.5k
Ω
10
20~30
30~40
Dryer
Temperature
40~50
50~60
60
With White9,White 6 disconnected from
Controller, check
1) High temperature thermistor ( Wire
color : White) White 6 pin
white ~White
6 pin
red resistance ranges table data
according to surrounding temperature.
2) Low temperature thermistor ( Wire
color : Blue) White 9 pin
Blue ~White 9
pin
white resistance ranges table data
according to surrounding temperature.
• Check and replace
thermistor.
1) Check disconnected
Housing or severed
Wire.
2) Check the resistance
of thermistor.
3) Replace controller
and then recheck,
if anything else
occurs.
29
Summary of Contents for RC7055*P*Z
Page 9: ...PROGRAM CYCLE 4 9 ...
Page 12: ...INSTALLATION INSTRUCTIONS 5 12 ...
Page 14: ...MAINTENANCE INSTRUCTIONS 6 1 2 4 5 6 7 CAUTION 3 8 14 ...
Page 15: ...COMPONENT TESTING TIPS 7 15 ...
Page 18: ...WIRING DIAGRAM 8 18 ...
Page 20: ...TROUBLESHOOTING 9 20 ...
Page 21: ...Error Mode TROUBLESHOOTING 9 21 ...
Page 55: ...AUGUST 2011 PRINTED IN KOREA P No 3828EL9001Y ...