80
INSTALLATION INSTRUCTIONS
ENGLISH
Installer Setting - Option Function Setting
Setting feature for indoor unit when plasma purification / electric heater / humidifier / elevation
grill / ventilation kit / auxiliary heater is newly installed, or installed unit is removed.
Function Code
Existing condition
Select existing condition
of each code by pressing
buttons.
(00: not installed,
01 : installed)
3
Press button to save.
4
Press the button for 3 seconds
to enter the Thermostat installer
setting
If pressed for a shorter time, it
enters into user setup mode.
1
Press the button to select the option
function code as pictured below.
2
Press the button to exit settings mode.
After setup, it automatically exits after 25
seconds if there is no input. If the
Setting/Cancel button is not pressed, the
mode will not change.
❈
In case of indoor unit that has one
more additional stage in the Aux
heater setting.
00: not installed
01: installed - general
02: installed - duct type
5
Function
Plasma purification
Electric heater
Humidifier
Elevation grill
Ventilation kit
Auxiliary heater
Code
20
21
22
23
24
25
Summary of Contents for PREMTB10U