Rack Installation
Typical Rack Installation
1 To avoid causing electrostatic (ESD) damage to the PCS500R during installation, attach an antistatic wrist
strap to a properly grounded rack/object and put it on.
2
(Optional) As shipped, the PCS500R mounting brackets are attached flush with the front of the unit (see
diagram a). If desired, the mounting brackets may be detached from the unit and reattached, for example, so
that they are flush with the rear of the unit (see diagram b). If you wish to change the location/orientation of
the mounting brackets, carefully remove each of the four (M4 x 10 mm) screws and attendant washers (one
flat and one lock washer per screw) holding each bracket in place. Then, use the same screws and washers to
reattach the mounting brackets in the desired location.
3 Carefully slide the chassis into a standard 48.2 cm equipment rack.
4 Use all four mounting screws to secure the chassis to the rack.
(A)
PWR
POWER
19 V DC
Service Port
USB
Feature Port Control Port
RF-TAP
RF-OUT
To rack
To rack
(B)
PWR
POWER
19 V DC
Service Port
USB
Feature Port Control Port
RF-TAP
RF-OUT
Use flat washer and lock washer with each M4 x 10 mm mounting bracket screw.