ELECTRICAL WIRING
ENGLISH
Display
Title
Cause of Error
Outdoor unit related error
1 5 3
1
Master Outdoor Unit Heat Exchanger
Temperature Sensor (upper part) Fault
Master Outdoor Unit Heat Exchanger Temperature
Sensor (upper part) Fault
2
Slave1 Outdoor Unit Heat Exchanger
Temperature Sensor (upper part) Fault
Slave1 Outdoor Unit Heat Exchanger Temperature
Sensor (upper part) Fault
3
Slave2 Outdoor Unit Heat Exchanger
Temperature Sensor (upper part) Fault
Slave2 Outdoor Unit Heat Exchanger Temperature
Sensor (upper part) Fault
4
Slave3 Outdoor Unit Heat Exchanger
Temperature Sensor (upper part) Fault
Slave3 Outdoor Unit Heat Exchanger Temperature
Sensor (upper part) Fault
1 5 4
1
Master Outdoor Unit Heat Exchanger
Temperature Sensor (lower part) Fault
Master Outdoor Unit Heat Exchanger Temperature
Sensor(lower part) open or short
2
Slave1 Outdoor Unit Heat Exchanger
Temperature Sensor (lower part) Fault
Slave1 Outdoor Unit Heat Exchanger Temperature
Sensor (lower part) open or short
3
Slave2 Outdoor Unit Heat Exchanger
Temperature Sensor (lower part) Fault
Slave2 Outdoor Unit Heat Exchanger Temperature
Sensor(lower part) open or short
4
Slave3 Outdoor Unit Heat Exchanger
Temperature Sensor (lower part) Fault
Slave3 Outdoor Unit Heat Exchanger Temperature
Sensor(lower part) open or short
1
8
2
1
Master outdoor unit External Board
Main-Sub Micom communication Error
Master Outdoor Unit Main Board Main-Sub Micom
communication failed
2
Slave1 outdoor unit External Board
Main-Sub Micom communication Error
Slave1 Outdoor Unit Main Board Main-Sub Micom
communication failed
3
Slave2 outdoor unit External Board
Main-Sub Micom communication Error
Slave2 Outdoor Unit Main Board Main-Sub Micom
communication failed
4
Slave3 outdoor unit External Board
Main-Sub Micom communication Error
Slave3 Outdoor Unit Main Board Main-Sub Micom
communication failed
1
9
3
1
Master Outdoor Unit Fan Heatsink High
Temperature
System is turned off by Master Outdoor Unit Fan
Heatsink High Temperature
2
Slave1 Outdoor Unit Fan Heatsink High
Temperature
System is turned off by Slave1 Outdoor Unit Fan
Heatsink High Temperature
3
Slave2 Outdoor Unit Fan Heatsink High
Temperature
System is turned off by Slave2 Outdoor Unit Fan
Heatsink High Temperature
4
Slave3 Outdoor Unit Fan Heatsink High
Temperature
System is turned off by Slave3 Outdoor Unit Fan
Heatsink High Temperature
1
9
4
1
Master Outdoor Unit Fan Heatsink
Temperature Sensor Fault
Master Outdoor Unit Fan Heatsink Temperature Sen-
sor open or short
2
Slave1 Outdoor Unit Fan Heatsink Tem-
perature Sensor Fault
Slave1 Outdoor Unit Fan Heatsink Temperature Sen-
sor open or short
3
Slave2 Outdoor Unit Fan Heatsink Tem-
perature Sensor Fault
Slave2 Outdoor Unit Fan Heatsink Temperature Sen-
sor open or short
4
Slave3 Outdoor Unit Fan Heatsink Tem-
perature Sensor Fault
Slave3 Outdoor Unit Fan Heatsink Temperature Sen-
sor open or short