18
<Example : If this unit receives signal from “Alarm 8”>
Alarm signal input
Before inputting
the alarm signal
Released alarm signal
Function status
Auto mode
While observe a
specific position.
Change the observe position to
the alarmed position then return
to the position that previously
observed.
While operating
Preset Tour func-
tion.
Stop preset touring and change
the observe position to the
alarmed position then restart the
preset touring again.
While operating
Auto Pan func-
tion.
Stop auto panning and change
the observe position to the
alarmed position then restart the
auto panning again.
While operating
Pattern function.
Stop operating pattern func-
tion and change the observe
position to the alarmed position
then restart the pattern function
again.
Note:
The Alarm In 1 is Preset 1, Alarm In 2 is Preset 2,
Alarm In 3 is Preset 3,...,Alarm In 7 is Preset 7 and
Alarm In 8 is Preset 8.
ALARM OUT connections
Connect an external device, for example, a buzzer or
lamp, to this connector. Output specifications are low-
active, open-collector and a drive capacity of 30V DC
0.5A maximum.
Alarm output numbers 1 to 4 are linked to alarm
inputs 1 to 4 respectively. If alarm input 1 comes in,
the camera sends output signals via the alarm output
1 connector on the camera.
Note:
Use a relay if the voltage or current of the connected
device exceeds the ratings.