11
Installation
Dipswitch Setting
The camera has one 8 bit switches that determine the
protocol and baud rate of the data communication.
Settings are loaded when the camera boots up. Be
sure to turn the camera off, change the dipswitch set-
tings, then power back up to load the changes.
1. Turn off the camera.
2. Remove the dome cover from the housing.
3. Set the dipswitches inside the housing as per the
table below.
4. Power up the camera to load the changes.
SW on main board
ON
1
2
3
4
5
6
7
8
Switch position (5-8)
Protocol
ON
1
2
3
4
5
6
7
8
(OFF OFF OFF OFF)
LG Multix
ON
1
2
3
4
5
6
7
8
(ON OFF OFF OFF)
Reserved 1
ON
1
2
3
4
5
6
7
8
(OFF ON OFF OFF)
Pelco D
ON
1
2
3
4
5
6
7
8
(ON ON OFF OFF)
Pelco P
Note:
If you are not using the controller with LG Multix proto-
col, there may be some limitation of function control.
Switch position (1-4)
BAUD RATE
ON
1
2
3
4
5
6
7
8
(OFF OFF OFF OFF)
9,600 BPS
ON
1
2
3
4
5
6
7
8
(ON OFF OFF OFF)
1,200 BPS
ON
1
2
3
4
5
6
7
8
(OFF ON OFF OFF)
2,400 BPS
ON
1
2
3
4
5
6
7
8
(ON ON OFF OFF)
4,800 BPS
ON
1
2
3
4
5
6
7
8
(OFF OFF ON OFF)
19,200 BPS
ON
1
2
3
4
5
6
7
8
(ON OFF ON OFF)
38,400 BPS
ON
1
2
3
4
5
6
7
8
(OFF ON ON OFF)
57,600 BPS
ON
1
2
3
4
5
6
7
8
(ON ON ON OFF)
115,200 BPS
Summary of Contents for LT703
Page 32: ...P NO MFL62034715 ...