Alarm Output Mode Setting
You can set the Alarm Output to the normal open or
normal close mode.
SW1 on IF board
ON
1
2
3
4
5
6
7
8
Alarm
Output
Number
Switch
Number
(Position)
Function Effect
1
1 (ON), 2 (OFF)
Normal Open mode
1 (OFF), 2 (ON)
Normal Close mode
2
3 (ON), 4 (OFF)
Normal Open mode
3 (OFF), 4 (ON)
Normal Close mode
3
5 (ON), 6 (OFF)
Normal Open mode
5 (OFF), 6 (ON)
Normal Close mode
4
7 (ON), 8 (OFF)
Normal Open mode
7 (OFF), 8 (ON)
Normal Close mode
Camera ID Setting
If you want to use multiple cameras, you should set
camera IDs differently by using the 8-bit Dip switch for
each camera.
Set the camera ID setting referring to the pictures and
the table on the below.
• The default setting of the camera ID is 0.
SW1 on main board
ON
1
2
3
4
5
6
7
8
The table for the camera ID setting
ID
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
0
OFF OFF OFF OFF OFF OFF OFF OFF
1
ON OFF OFF OFF OFF OFF OFF OFF
2
OFF ON OFF OFF OFF OFF OFF OFF
3
ON
ON OFF OFF OFF OFF OFF OFF
4
OFF OFF ON OFF OFF OFF OFF OFF
5
ON OFF ON OFF OFF OFF OFF OFF
6
OFF ON
ON OFF OFF OFF OFF OFF
7
ON
ON
ON OFF OFF OFF OFF OFF
8
OFF OFF OFF ON OFF OFF OFF OFF
9
ON OFF OFF ON OFF OFF OFF OFF
10
OFF ON OFF ON OFF OFF OFF OFF
11
ON
ON OFF ON OFF OFF OFF OFF
12
OFF OFF ON
ON OFF OFF OFF OFF
13
ON OFF ON
ON OFF OFF OFF OFF
14
OFF ON
ON
ON OFF OFF OFF OFF
15
ON
ON
ON
ON OFF OFF OFF OFF
16
OFF OFF OFF OFF ON OFF OFF OFF
17
ON OFF OFF OFF ON OFF OFF OFF
18
OFF ON OFF OFF ON OFF OFF OFF
19
ON
ON OFF OFF ON OFF OFF OFF
20
OFF OFF ON OFF ON OFF OFF OFF
21
ON OFF ON OFF ON OFF OFF OFF
22
OFF ON
ON OFF ON OFF OFF OFF
23
ON
ON
ON OFF ON OFF OFF OFF
24
OFF OFF OFF ON
ON OFF OFF OFF
Summary of Contents for LT703