Installation
6RMI0-04C
77
Inverter Single
Forming the Piping
In cases where the outdoor unit is
installed below the indoor unit
perform the following.
1. Tape the piping, drain hose and connecting cable
from down to up.
2. Secure the tapped piping along the exterior wall
using saddle or equivalent.
In cases where the Outdoor unit is
installed above the Indoor unit
perform the following.
1. Tape the piping and connecting cable from down to
up.
2. Secure the taped piping along the exterior wall.
Form a trap to prevent water entering the room.
3. Fix the piping onto the wall using saddle or
equivalent.
Trap is required to prevent water
from entering into electrical parts.
Taping
Saddle
Drain hose
Pipings
Connecting cable
(Conduit)
Seal the small
openings around
pipings with a gum
type sealants.
Trap
Trap
Seal the small openings
around pipings with a