Capacity tables
6RMI0-05A
39
Inverter Single
AS-W123F2B2(LAN120HVP/LAU120HVP)
Symbol
DB : Dry Bulb Temperature [°C(°F)]
WB : Wet Bulb Temperature [°C(°F)]
TC : Total Capacity [kBtu/h]
SHC : Sensible Heating Capacity [kBtu/h]
PI : Power Input [kW]
(Comp.+ indoor fan motor + outdoor fan motor)
Notes
1. All capacities are net, evaporator fan motor heat is deducted.
2.
Indicates nominal maximum capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m(24.6 ft)
- Level Difference of Zero.
Indoor Air
Temperature
Outdoor Air Temperature : DB°C(°F)
20(68)
25(77)
32(89.6)
35(95)
10.97
8.94
0.52
10.50
11.65
9.06
0.70
11.17
12.33
9.14
0.76
11.84
12.66
9.22
0.76
12.18
13.68
9.40
0.76
13.19
14.35
9.57
0.76
13.86
14(57.2)
20(68.0)
16(60.8)
22(71.6)
18(64.4)
25(77.0)
19(66.2)
27(80.6)
22(71.6)
30(86.0)
24(75.2)
32(89.6)
Indoor Air
Temperature
Outdoor Air Temperature : DB°C(°F)
40(104)
43(109.4)
46(114.8)
48(118.4)
9.14
7.78
0.89
8.88
9.80
7.96
0.95
9.55
10.47
8.11
0.97
10.22
10.80
8.21
0.97
10.55
11.80
8.47
0.99
11.55
12.46
8.69
1.01
12.21
14(57.2)
20(68.0)
16(60.8)
22(71.6)
18(64.4)
25(77.0)
19(66.2)
27(80.6)
22(71.6)
30(86.0)
24(75.2)
32(89.6)
WB°C (°F)
DB°C (°F)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
WB°C (°F)
DB°C (°F)
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
8.65 0.54 9.86 8.30 0.72 9.56 8.02 0.81
8.79 0.70 10.52 8.46 0.85 10.22 8.19 0.92
8.88 0.76 11.19 8.58 0.90 10.89 8.32 0.93
8.97 0.77 11.53 8.68 0.90 11.19 8.39 0.93
9.17 0.78 12.53 8.91 0.93 12.22 8.65 0.98
9.35
0.79
13.20
9.11
0.94
12.88
8.86
1.00
9.35 0.79 13.20 9.11 0.94 12.88 8.86 1.00
7.50 0.87 8.63 7.27 0.78 8.40 7.21 0.73
7.70 0.91 9.30 7.47 0.79 9.06 7.42 0.72
7.85 0.91 9.97 7.64 0.77 9.73 7.59 0.69
7.96 0.90 10.3 7.75 0.76 10.06 7.70 0.68
8.23 0.91 11.3 8.03 0.76 11.06 7.99 0.67
8.45 0.93 11.96 8.25 0.78 11.73 8.22 0.69