- 65 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
■
The problem of missing the connector (INDOOR MAIN PCB ASSY)
Connectors
CN-POWER
(AC2)
CN-FAN
CN-DATA
CN-DISP1
CN-DISP2
CN-TH
CN-U/D
Condition
OPEN
OPEN
OPEN
OPEN
OPEN
OPEN/SHORT
OPEN
• Malfunctions all indoor & outdoor unit.
• Malfunctions remocon, force, test operation mode.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan motor.
• The operation LED blinks 5 times.
• Communicaion error.
• Malfunctions remote contoller.
• Don't operate the power display module.
• Don't operate the power display module.
(LS-_NM/NN Series is not included)
• The operation LED blinks twice.
• Enable to receive remote singnal.
• Malfunctions UP/DOWN step motor.
• Don't operate louver.
• Malfunctions indoor fan motor.
Problem (error mode)