5. Healthy Dehumidification mode operation
• When the dehumidification operation is set by the remote controller the intake air temperature is detected and
the setting temp. is automatically set according to the intake air temperature.
• Operating frequency of compressor and indoor fan speed.
Temp. differences
32°C
≤
intake air temp.
26°C
≤
intake air temp. < 32°C
24°C
≤
intake air temp.< 26°C
18°C < intake air temp. < 24°C
intake air temp.
≤
18°C
Comp. Operating frequency
25°C
25°C
intake air temp. -1°C
intake air temp. -0.5°C
18°C
Cooling operation area
Dehumidification
operation area
After 3 min off
OFF instantly
Low
speed
Low
speed
After 5 min OFF
low speed
Setting
speed
+1.0˚C
+0.5˚C
Setting temp. +0˚C
-1.0˚C
-2.0˚C
Operating frequency of compressor
Indoor fan speed
Step 3
Step 2
Step 1