3) Connection of Pipings(11K,12K, 14K BTU)
1. Remove the indoor tubing with Drain hose to the
hole
• Remove tubing holder and pull the tubing out of the
chassis.
- 28 -
2. Refix the tubing holder into original position.
3. Route the tubing and the drain hose straight
backwards(see figure).
4. Insert the connection cable into the indoor unit
through the piping hole.
• Do not connect the cable to the indoor unit.
• Make a small loop with the cable for easy connec-
tion later.
5. Tape the tubing, drain hose and the connecting
cable.
For right rear piping
;
;
;
Tubing holder
Pull
Press
11K, 12K, 14K Series
• To remove the holder, press
the bottom of the chassis
near the holder upwards and
the tab is clear of its hole.
• Turn it clockwise approx.
90°C and remove it.
Outdoor
Indoor
Drain pipe
Connecting piping
Connecting cable
Taping
Gas side piping
Liquid side piping
Drain hose
Connecting
cable
Indoor/Outdoor
Connecting cable