4-4
Broil element
Bake element
Convection element
Warming Drawer element
1. Refer to page 3-6 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Components
Test procedures
Results
Normal: Approximately
14
Ω
± 10%
If not replace
1. Refer to page 3-7 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
17
Ω
± 10%
If not replace
1. Refer to page 3-8 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
17
Ω
± 10%
If not replace
1. Refer to page 3-12 for the servicing procedure
2. Measure the resistance after cooling down
(Multiple meter scale: R x1)
Normal: Approximately
95
Ω
± 10%
If not replace
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE:
Ω
Value was tested
at room temperature
(77F/25˚C)
Be careful the element is
sensitive to temperature.
NOTE: ONLY ON MODEL
LRE30755
Summary of Contents for LRE30451
Page 1: ...Service Digital Appliance TRAINING MANUAL ELECTRIC RANGE LRE30451 LRE30755 ...
Page 8: ......
Page 9: ......
Page 11: ...j j j j LRE30451 LRE30755 ...
Page 67: ...8 1 APPENDIX A SCHEMATIC DIAGRAM OF PCB ...
Page 73: ...10 3 WARMNING DRAWER SELF CLEANING For Model LRE30755SW SB ST ...
Page 74: ...10 4 CLOCK DISPLAY ON CR Warming Zone CONV BAKE CONV ROAST For Model LRE30755SW SB ST ...
Page 90: ......
Page 91: ......
Page 92: ......