4-2
Door locking Motor
Micro Switch
(normally open type)
LVT
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-10 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
1. Refer to page 3-3 for the servicing procedure
2. Measure the resistance
(Multiple meter scale: R x 1000)
Normal: Approximately
27
Ω
± 10%
If not replace
Components
Test procedures
Results
NO
COM
Normal: Approximately
2.6 k
Ω
± 10%
If not replace
Abnormal: Infinite(open)
below 5
Ω
(shorted)
Door latch
open
Door latch
Locked
Continuity
Infinite
NOTE: After checking for the continuity of switch, make sure that they are
connected correctly
Summary of Contents for LRE30451
Page 1: ...Service Digital Appliance TRAINING MANUAL ELECTRIC RANGE LRE30451 LRE30755 ...
Page 8: ......
Page 9: ......
Page 11: ...j j j j LRE30451 LRE30755 ...
Page 67: ...8 1 APPENDIX A SCHEMATIC DIAGRAM OF PCB ...
Page 73: ...10 3 WARMNING DRAWER SELF CLEANING For Model LRE30755SW SB ST ...
Page 74: ...10 4 CLOCK DISPLAY ON CR Warming Zone CONV BAKE CONV ROAST For Model LRE30755SW SB ST ...
Page 90: ......
Page 91: ......
Page 92: ......